subject
Engineering, 12.08.2020 16:01 RoyALP

You have to design a network between 7 cities, (A thru F are arranged forming an hexagon and the seventh "G" is the center). Consider carefully the design restrictions because you have a limited number of components and the fiber distance is also a limitation. There will be an optical switch in each city that supports 5 ports. Each port is a pair of fibers, one for transmission and the other for reception.
Each fiber supports 4 colors ( C1 to C4).
Each switch can handle 20 independent connections ( 5 ports, 4 colors each).
One port must be reserved for the traffic destination in the city, the remaining four are for long distance.
The max distance for a fiber link with no amplifiers is 100 KM.
All distances between neighbor cities are 100 km (not the actual logic links or light-paths).
There are only 4 EDFA available.
There are 10 grating devices (color splitters / combiners for both directions)
Create a design that will allow at least four connections from each city to other four. (Only Four fiber pairs allowed to terminate in a city).
Include the total cost of your solution for bonus 10 points:
The cost of a switch is $100K, an amplifier is $50K, 100km of fiber are $1M. (grating cost is not considered)
Provide:
1. Diagram of the detailed structure of the switch design.
2. City map diagram illustrating the physical fiber connectivity
3. Color links between different cities (when they are not directly attached through a direct fiber, try to avoid interference)
4. Turn in scanned procedure before deadline.

ansver
Answers: 1

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Aturning operation is performed with following conditions: rake angle of 12°, a feed of 0.35 mm/rev, and a depth of cut of 1.1 mm. the work piece is aluminum alloy 6061 with t6 heat treatment (a16061-t6). the resultant chip thickness was measured to be 1.0 mm. estimate the cutting force, fc. use shear stress of 207 mpa and coefficient of friction on the tool face of 0.6.
Answers: 1
question
Engineering, 04.07.2019 18:20
Most leaks in reciprocating air compressors can be detected and minimized by: (clo4) a)-detecting leakage areas using ultrasonic acoustic detector. b)-tightening joints and connections c)-replacing faulty equipment d)-all of the given options
Answers: 2
question
Engineering, 04.07.2019 18:20
Vibration monitoring this technique uses the noise or vibration created by mechanical equipment and in seme cases by plant systems to detemine their actual condtion. a)- true b)- false
Answers: 2
question
Engineering, 04.07.2019 18:20
Along 8-cm diameter steam pipe whose external surface temperature is 900c connects two buildings. the pipe is exposed to ambient air at 70c with a wind speed of 50 km/hr blowing across the pipe. determine the heat loss from the pipe per unit length. (b) air at 500c enters a section of a rectangular duct (15 cm x 20 cm) at an average velocity of 7 m/s. if the walls of the duct are maintained at 100c. a) the length of the tube for an exit temperature of the air to be 40 0c. b)the rate of heat transfer from the air. c) the fan power needed to overcome the pressure drop in this section of the duct.
Answers: 1
You know the right answer?
You have to design a network between 7 cities, (A thru F are arranged forming an hexagon and the sev...
Questions
question
Mathematics, 24.03.2021 21:40
question
English, 24.03.2021 21:40
question
Advanced Placement (AP), 24.03.2021 21:40
question
Mathematics, 24.03.2021 21:40
question
Mathematics, 24.03.2021 21:40