subject
Engineering, 06.05.2020 03:37 AjTruu2880

Concrete is required for an interior concrete column in a commercial building in Corvallis, Oregon. A specified compressive strength, f'c, of 4000 psi is required at 28 days using an ASTM C 150 Type I. The design calls for a minimum of 3 in. of concrete cover over the reinforcing steel. The minimum distance between reinforcing bars is 2.5 in. A slump of 4 inches should be the target. No statistical data on previous mixes are available. Follow mixture proportioning according to Portland Cement Association (PCA) - Design and Control of Concrete Mixtures, Kosmatka and Wilson, 201 16'h Edition. Materials Available: ASTM C 150 Type IVII Cement Relative density of 3.15 Coarse Aggregate: well-graded ' in. maximum-size aggregate (MSA), local river gravel Oven-dry specific gravity: 2.60 Absorption : 1.2% Oven-dry rodded bulk density: 102.4 lb/ft3 Moisture content of coarse stockpile: 3.0% Fine Aggregate: well-graded, local natural sand Oven-dry specific gravity: 2.55 Absorption: 2.0% Moisture content of fine stockpile: 3.8% Fineness Modulus: 2.60

ansver
Answers: 2

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Determine whether or not it is possible to compress air adiabatically from k to 140 kpa and 400 k. what is the entropy change during this process?
Answers: 3
question
Engineering, 04.07.2019 18:10
Water in a partially filled large tank is to be supplied to the roof top, which is 8 m above the water level in the tank, through a 2.2-cm-internal-diameter pipe by maintaining a constant air pressure of 300 kpa (gage) in the tank. if the head loss in the piping is 2 m of water, determine the discharge rate of the supply of water to the roof top in liters per second.
Answers: 3
question
Engineering, 04.07.2019 18:10
Carbon dioxide gas expands isotherm a turbine from 1 mpa, 500 k at 200 kpa. assuming the ideal gas model and neglecting the kinetic and potential energies, determine the change in entropy, heat transfer and work for each kilogram of co2.
Answers: 2
question
Engineering, 04.07.2019 18:20
Ahe-xe mixture containing a 0.75 mole fraction of helium is used for cooling electronics in an avionics application. at a temperature of 300 k and atmospheric pressure, calculate the mass fraction of helium and the mass density, molar concentration and molecular weight of the mixture. if the cooling capacity is 10 l, what is the mass of the coolant?
Answers: 3
You know the right answer?
Concrete is required for an interior concrete column in a commercial building in Corvallis, Oregon....
Questions
question
Mathematics, 17.11.2019 23:31