Engineering, 14.04.2020 19:35 rhodesnyla01

A 12.5-kW, 230-V shunt motor has 2400 shunt-field turns per pole, an armature resistance (including brushes) of 0.18Ω, and a commutating-field resistance of 0.035Ω. The shunt-field resistance (exclusive of rheostat) is 375Ω. When the motor is operated at no load with rated terminal voltage and varying shunt-field resistance, the following data are obtained:

The no-load armature current is negligible. When the motor is operating at full load and rated terminal voltage with a field current of 0.468 A, the armature current is 58.2 A and the speed is 1770 r/min.

a. Calculate the full-load armature reaction in equivalent demagnetizing ampere-turns per pole.
b. Calculate the electromagnetic and load torques and the rotational loss at the given operating condition.
c. What starting torque will the motor produce with a field current of 0.555 A if the starting armature current is limited to 85A? Assume that the armature reaction under these conditions is equal to 175 ampere-turns per pole.
d. Design a series field winding to give a speed of 1575 r/min when the motor is loaded to an armature current of 58.2 A and when the shunt field current is adjusted to give a no-load speed of 1800 r/min. Assume the series field will have a resistance of 0.045 Ω.

ansver
Answers: 2

Another question on Engineering

question
Engineering, 03.07.2019 14:10
Amass of 1.5 kg of air at 120 kpa and 24°c is contained in a gas-tight, frictionless piston-cylinder device. the air is now compressed to a final pressure of 720 kpa. during the process, heat is transferred from the air such that the temperature inside the cylinder remains constant. calculate the boundary work input during this process.
Answers: 2
question
Engineering, 03.07.2019 14:10
Line joining liquid phase with liquid and solid phase mixture is known as: a) liquidus b) solidus c) tie line d) none of the mentioned
Answers: 2
question
Engineering, 04.07.2019 18:20
The characteristic roots of a dynamic system are: 1.7920 1.8160 i, -1.7920 1.8160 i, -0.4160 what is the order of this system? what are the settling time and damping ratio of the system?
Answers: 3
question
Engineering, 04.07.2019 18:20
Prove the equivalence between the two statements of the 2nd law of thermodynamics (i.e., a violation of one statement leads to the violatio the other statement)
Answers: 2