Consider a proposed offshore wind farm composed of 106 siemens direct drive wind turbines each with a rated capacity of 6.00 mw. each wind turbine has a rotor diameter of 154 meters, an effectiveness of 67.5%, and a generator efficiency of 96.0%. the array efficiency is 80.0%. it is estimated that the wind farm will generate 2500 gwh of electricity annually. each wind turbine requires 400 hours of maintenance annually. the density of air is 1.225 kg/m3.

a. what is the coefficient of performance for the turbine rotor (%)

b. what is the overall efficiency of the proposed wind farm (%)?

c. what is the capacity factor of the proposed wind farm (%)?

d. what is the swept area of the proposed wind turbines (m2)?

e. what is the rated wind speed for the proposed wind turbines (m/s)?

f. what is the availability of the proposed wind turbines (%)?

ansver
Answers: 1

Another question on Engineering

question
Engineering, 04.07.2019 18:10
An air conditioning system consist of a 5 cm diameter pipe, operating at a pressure of 200 kpa. the air initially enters the pipe at 15°c with a velocity of 20 m/s and relative humidity of 80%. if the heat supply throughout the process is 960 w, determine the relative humidity and the temperature at the outlet
Answers: 3
question
Engineering, 04.07.2019 18:20
An engine runs on the ideal diesel cycle. the cycle has a compression ratio of 20 and a cutoff ratio of 2. the highest temperature in the cycle is 1200 k. if the heat into the system is 300 kj/kg of working fluid and using variable specific heats determine the work produced per mass of working fluid
Answers: 3
question
Engineering, 04.07.2019 19:10
When subject to a steady load (within elastic range) over a long period of time, what is the major difference in material behavoir between steel and plastic?
Answers: 2
question
Engineering, 04.07.2019 19:20
Acommercial grade cubical freezer, 4 m on a side, has a composite wall consisting of an exterior sheet of 5.0-mm thick plain carbon steel (kst= 60.5 w/m k), an intermediate layer of 100-mm thick polyurethane insulation (kins 0.02 w/m k), and an inner sheet of 5.0- mm thick aluminium alloy (kal polyurethane insulation and both metallic sheets are each characterized by a thermal contact resistance of r 2.5 x 104 m2 k/w. (a) what is the steady-state cooling load that must be maintained by the refrigerator under conditions for which the outer and inner surface temperatures are 25°c and -5°c, respectively? (b) for power saving purpose, which wall material should be increased/reduced in. thickness in order to reduce 50% of the cooling load found in part (a)? redesign the thickness of the proposed material. 177 w/m-k). adhesive interfaces between the q=575.93 w
Answers: 2
You know the right answer?
Consider a proposed offshore wind farm composed of 106 siemens direct drive wind turbines each with...
Questions
question
Biology, 13.11.2020 22:30
question
Biology, 13.11.2020 22:30
question
Mathematics, 13.11.2020 22:30