subject
Engineering, 27.08.2019 20:20 mxhx

Design a tower intake to be placed in a reservoir in a warm climate. provide the minimum number of ports. the design conditions are: summer design flow rate = 38,000 m^3/d maximum reservoir elevation = 499.0 m minimum reservoir elevation = 480.7 m lake bottom elevation = 477.7 m bar rack bars: 1 cm diameter: 8 cm between bars specify the following: number and location of intake ports spacing of the ports depth of lowest port depth of top port dimensions of a port provide a sketch of the following: intake tower with elevations of ports, reservoir elevations, and lake bottom elevation

ansver
Answers: 3

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Water at 55c flows across a flat plate whose surface temperature is held constant at 95c. if the temperature gradient at the plate's surface for a given value of x is 18 c/mm, find a) local heat transfer coefficient. b) heat flux
Answers: 3
question
Engineering, 04.07.2019 18:10
Ifa component is made of two or more materials with different modulus of elasticity (e), it is called a composite member and we calculate the factor·n". mention the formula for calculating n". also, ifn> 1, explain what will happen to the 1. transformed.gi) ifn 1, what will happen to the material when transformed material when
Answers: 1
question
Engineering, 04.07.2019 19:10
Tom is having a problem with his washing machine. he notices that the machine vibrates violently at a frequency of 1500 rpm due to an unknown rotating unbalance. the machine is mounted on 4 springs each having a stiffness of 10 kn/m. tom wishes to add an undamped vibration absorber attached by a spring under the machine the machine working frequency ranges between 800 rpm to 2000 rpm and its total mass while loaded is assumed to be 80 kg a) what should be the mass of the absorber added to the machine so that the natural frequency falls outside the working range? b) after a first trial of an absorber using a mass of 35 kg, the amplitude of the oscillation was found to be 10 cm. what is the value of the rotating unbalance? c) using me-3.5 kg.m, find the optimal absorber (by minimizing its mass). what would be the amplitude of the oscillation of the absorber?
Answers: 3
question
Engineering, 04.07.2019 19:10
Arigid tank contains 10 kg of air at 137 kpa (abs) and 21°c. more air is added to the tank until the pressure and temperature rise to 242 kpa (abs) and 32°c, respectively. determine the amount of air added to the tank. [r-0.287 kj/kg k]
Answers: 3
You know the right answer?
Design a tower intake to be placed in a reservoir in a warm climate. provide the minimum number of p...
Questions
question
Mathematics, 03.12.2021 20:50
question
Mathematics, 03.12.2021 20:50
question
History, 03.12.2021 20:50
question
Chemistry, 03.12.2021 20:50
question
Mathematics, 03.12.2021 20:50
question
Social Studies, 03.12.2021 20:50