subject
Engineering, 20.08.2019 18:30 ciaotaylor

Consider a piston-cylinder assembly located in a room at 100 kpa and in which a saturated liquid+vapor mixture of h2o exists with a quality of 0.5. heat is added until the specific volume is tripled. neglect changes in potential and kinetic energy. neglect the mass of the piston. a. draw the process and label the states on a t-v diagram. b. draw the process and label the states on a p-v diagram. c. determine the boundary work per unit mass. d. determine the heat transfer per unit mass. e. determine the entropy produced per unit mass if the boundary temperature is 200°c.

ansver
Answers: 3

Another question on Engineering

question
Engineering, 04.07.2019 18:20
The characteristic roots of a dynamic system are: 1.7920 1.8160 i, -1.7920 1.8160 i, -0.4160 what is the order of this system? what are the settling time and damping ratio of the system?
Answers: 3
question
Engineering, 04.07.2019 18:20
Air flows over a heated plate àt a velocity of 50m/s. the local skin factor coefficient at a point on a plate is 0.004. estimate the local heat transfer coefficient at this point.the following property data for air are given: density = 0.88kg/m3 , viscosity 2.286 x 10 ^-5 kgm/s , k = 0.035w/mk ,cp = 1.001kj/kgk. use colburn reynolds analogy.
Answers: 1
question
Engineering, 04.07.2019 19:20
Determine the time of the day and month of the year at which the peak sensible cooling load occurs for a top floor, north-eastern corner room of an office building in durban for the following conditions: floor area: 8 x 8 x 3 m east and north walls: 115 mm face brick (outside), 20 mm air space, 115 mm ordinary brick (inside) with 15 mm plaster roof construction: suspended plasterboard ceiling, 450 mm air space, 150 mm concrete, 75mm screed, waterproofing no heat transfer across other surfaces window area 3x 1,5 m high in north wall only. ordinary glass with venetian blinds. lights and occupants : from 07: 00 to 18: 00 average light density: 25 w/m2 number of occupants : 5 seated, light office work room temperature 24°c
Answers: 3
question
Engineering, 06.07.2019 03:10
Oxygen at 300 kpa and 400 k is in a closed system with an initial volume of 0.1 m3. is now compressed in a polytropic process, with exponent of n 1.2, to a temperature of 500 k. calculate: a) the boundary work done during the compression, in kj b) the heat transfer during the compression, in kj
Answers: 3
You know the right answer?
Consider a piston-cylinder assembly located in a room at 100 kpa and in which a saturated liquid+vap...
Questions
question
English, 16.06.2021 05:00
question
History, 16.06.2021 05:00
question
Mathematics, 16.06.2021 05:00
question
Computers and Technology, 16.06.2021 05:00