subject
Engineering, 11.07.2019 04:10 bestkitty2588

Consider an electrically heated melting furnace in the shape of a truncated cone with a height of 7.5m and a base diameter of 5m. at the top of the furnace is an opening with diameter 2.5m. is proposed to place a disk-shaped covering with hole diameter 1.5m to reduce energy losses while still allowing for the charging of materials to keep the furnace in continuous operation. (i) determine the power required to opcrate the furnace such that, when cmpty (i. e under preheat), the surface temperatures of the conical sides are at 1000°c and the surface temperature of the base is50°c. the ambient temperature at the top of the furnace is 300°c. (2)-calculate the percent reduction in energy if the covering is used, assuming the same ambient temperature as that given above.

ansver
Answers: 2

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Water in a partially filled large tank is to be supplied to the roof top, which is 8 m above the water level in the tank, through a 2.2-cm-internal-diameter pipe by maintaining a constant air pressure of 300 kpa (gage) in the tank. if the head loss in the piping is 2 m of water, determine the discharge rate of the supply of water to the roof top in liters per second.
Answers: 3
question
Engineering, 04.07.2019 18:20
An engine runs on the ideal diesel cycle. the cycle has a compression ratio of 20 and a cutoff ratio of 2. the highest temperature in the cycle is 1200 k. if the heat into the system is 300 kj/kg of working fluid and using variable specific heats determine the work produced per mass of working fluid
Answers: 3
question
Engineering, 04.07.2019 18:20
Refrigerant-134a enters the compressor of a refrigerator as superheated vapor at 0.14 mpa and -10°c at a rate of 0.05 ka/s and leaves at 0.8 mpa and 50°c. the refrigerant is cooied in the condenser to 0.72 mpa and 26'c. it is then throttled to 0.15 mpa. sketch the t-s diagram for the system and evaluate: 6) the rate of heat removai from the refrigerated space (kw), it) the power input to the compressor (kw), ii) the isentropic efficiency of the compressor (%), and iv) the cop of the refrigerator.
Answers: 2
question
Engineering, 04.07.2019 18:20
For each of the following process: a) sketch the p-v diagram, b)sketch t-s diagram, c) sketch t-v diagram, d) sketch the boundary work on one of the diagrams (a, b or c) and e) sketch the reversible heat transfer on one of the diagrams (a, b or c): 1- isobaric process from compressed liquid to superheated vapor 2- isothermal process from compressed liquid to superheated vapor 3- isentropic process from compressed liquid to superheated vapor
Answers: 3
You know the right answer?
Consider an electrically heated melting furnace in the shape of a truncated cone with a height of 7....
Questions