subject
Physics, 09.04.2021 20:10 miguelmike2895

A charge of 2.50 x 1016 elementary charges per second isatv equivalent to a current of amperes (A).

ansver
Answers: 3

Another question on Physics

question
Physics, 22.06.2019 02:00
Chapter 23, problem 075 the figure shows a geiger counter, a device used to detect ionizing radiation (radiation that causes ionization of atoms). the counter consists of a thin, positively charged central wire surrounded by a concentric, circular, conducting cylindrical shell with an equal negative charge. thus, a strong radial electric field is set up inside the shell. the shell contains a low-pressure inert gas. a particle of radiation entering the device through the shell wall ionizes a few of the gas atoms. the resulting free electrons (e) are drawn to the positive wire. however, the electric field is so intense that, between collisions with gas atoms, the free electrons gain energy sufficient to ionize these atoms also. more free electrons are thereby created, and the process is repeated until the electrons reach the wire. the resulting "avalanche" of electrons is collected by the wire, generating a signal that is used to record the passage of the original particle of radiation. suppose the radius of the central wire is 24 âµm, the inner radius of the shell 2.3 cm, and the length of the shell 14 cm. if the electric field at the shell's inner wall is 2.8 ă— 104 n/c, what is the total positive charge on the central wire?
Answers: 1
question
Physics, 22.06.2019 07:30
Some material consisting of a collection of microscopic objects is kept at a high temperature. a photon detector capable of detecting photon energies from infrared through ultraviolet observes photons emitted with energies of 0.3 ev, 0.5 ev, 0.8 ev, 2.0ev, 2.5ev, and 2.8ev. these are the only photon energies observed. (a) draw and label a possible energy-level diagram for one of the microscopic objects, which has four bound states. on the diagram, indicate the transitions corresponding to the emitted photons. explain briefly. (b) would a spring–mass model be a good model for these microscopic objects? why or why not? (c) the material is now cooled down to a very low temperature, and the photon detector stops detecting photon emissions. next, a beam of light with a continuous range of energies from infrared through ultraviolet shines on the material, and the photon detector observes the beam of light after it passes through the material. what photon energies in this beam of light are observed to be significantly reduced in intensity (“dark absorption lines”)? explain briefly.
Answers: 3
question
Physics, 22.06.2019 08:30
Determine the age of a fossil if it had only one eighth of its original carbon-14 content remaining?
Answers: 3
question
Physics, 22.06.2019 12:00
Asolid round steel rod 6.25 mm in diameter and 375 mm long is rigidly bonded to the end of solid square brass rod 25 mm on a side and 300 mm long. the geometric axes of the bare are along the same line. an axial tensile force of 5.4 kn is applied at the extreme ends of the assembly. for steel e = 200 gpa and for brass e = 90 gpa. determine the total elongation for the assembly.
Answers: 1
You know the right answer?
A charge of 2.50 x 1016 elementary charges per second isatv equivalent to a current of amperes (A)....
Questions