subject
Physics, 16.10.2020 20:01 caliharris123

You are deciding between using a 5000 ohm thermistor, Material System 1, or a class A RTD for measuring the temperature of a critical circuit board of a smart phone near 30°C. The accuracy must be within 0.25°C throughout the range of measurement. Neither speed of response nor component cost is an issue. The 5000-ohm thermistor is defined in the table below.

R25 Ω Material System B Value 25/85 °C/K Max Operaturing Temp° F (°C)

Code R25 °C + 1%

500 2 3540+/-1% 257 (125)

500 2A 3627+/-1% 257 (125)

1000 2 3540+/-1% 257 (125)

1000 2A 3627+/-1% 257 (125)

1800 2 3540+/-1% 257 (125)

2000 2 3540+/-1% 257 (125)

2000 2A 3627+/-1% 257 (125)

2200 1 3977+/-1% 311 (155) NK222C1*1

2700 1 3977+/-1% 311 (155) NK272C1*1

3000 1 3977+/-1% 311 (155) NK302C1*1

5000 1 3977+/-1% 311 (155) NK502C1*1

5000 4A 3436+/-1% 311 (155) NK502C4A1*1

10000 1 3977+/-1% 311 (155) NK103C1*1

You are deciding between using a 5000 ohm thermistor, Material System 1, or a class A RTD for measuring the temperature of a critical circuit board of a smart phone near 30°C. The accuracy must be within 0.25°C throughout the range of measurement. Neither speed of response nor component cost is an issue.

The 5000-ohm thermistor is defined in the table below.

Given the tolerance on β for the thermistor, what is the absolute value of the accuracy of the reading in °C that you will get on the thermistor at 30°C? (Type in a three-decimal number)

ansver
Answers: 1

Another question on Physics

question
Physics, 22.06.2019 05:40
Karen is running forward at a speed of 9 m/s. she tosses her sweaty headband backward at a speed of 20 m/s. the speed of the headband, to the nearest whole number relative to a stationary observer watching karen
Answers: 1
question
Physics, 22.06.2019 07:00
Oxygen and hydrogen gas are at the same temperature t.what is the ratio of kinetic energies of oxygen molecule and hydrogen molecule if oxygen is 16 times heavier than hydrogen.
Answers: 3
question
Physics, 22.06.2019 10:30
The precision of a laboratory instrument is ± 0.05 g. the accepted value for your measurement is 7.92 g. which measurements are in the accepted range? check all that apply. 7.85 g 7.89 g 7.91 g 7.97 g 7.99 g
Answers: 1
question
Physics, 22.06.2019 17:30
Aball thrown by ginger is moving upward through the air. diagram a shows a box with a downward arrow. diagram b shows a box with an upward arrow. diagram c shows a box with a downward and upward arrow equal in size. diagram d shows a box with a downward and upward arrow with the downward arrow larger in size. which force diagram represents the forces on the ball? you may neglect the effects of air resistance.
Answers: 3
You know the right answer?
You are deciding between using a 5000 ohm thermistor, Material System 1, or a class A RTD for measur...
Questions
question
Mathematics, 14.07.2021 23:30
question
Mathematics, 14.07.2021 23:30
question
Mathematics, 14.07.2021 23:30
question
Mathematics, 14.07.2021 23:30
question
Social Studies, 14.07.2021 23:30