An adiabatic open feedwater heater in an electric power plant mixes 0.2 kg/s of steam at 100 kpa and 160°c with 8.5 kg/s of feedwater at 100 kpa and 50°c to produce feedwater at 100 kpa and 60°c at the outlet. determine the outlet mass flow rate and the outlet velocity when the outlet pipe diameter is 0.03 m. the specific volume at the exit is 0.001017 m3/kg.

ansver
Answers: 2

Another question on Physics

question
Physics, 21.06.2019 21:40
Avery hard rubber ball (m = 0.5 kg) is falling vertically at 4 m/s just before it bounces on the floor. the ball rebounds back at essentially the same speed. if the collision with the floor lasts 0.05 s, what is the average force exerted by the floor on the ball?
Answers: 3
question
Physics, 22.06.2019 00:50
Acave rescue team lifts an injured spelunker directly upward and out of a sinkhole by means of a motor-driven cable. the lift is performed in three stages, each requiring a vertical distance of 10.0 m: (a) the initially stationary spelunker is accelerated to a speed of 4.90 m/s; (b) he is then lifted at the constant speed of 4.90 m/s; (c) finally he is decelerated to zero speed. how much work is done on the 68.0 kg rescue by the force lifting him during each stage?
Answers: 1
question
Physics, 22.06.2019 04:30
Light that is polarized along the vertical direction is incident on a sheet of polarizing material. only 96% of the intensity of the light passes through the sheet and strikes a second sheet of polarizing material. no light passes through the second sheet. what angle does the transmission axis of the second sheet make with the vertical?
Answers: 2
question
Physics, 22.06.2019 17:00
Air conditioners not only cool air, but dry it as well. suppose that a room in a home measures 5.0m×9.0m×2.4m . if the outdoor temperature is 30 ∘c and the vapor pressure of water in the air is 85 % of the vapor pressure of water at this temperature, what mass of water must be removed from the air each time the volume of air in the room is cycled through the air conditioner? the vapor pressure for water at 30 ∘c is 31.8 torr.
Answers: 3
You know the right answer?
An adiabatic open feedwater heater in an electric power plant mixes 0.2 kg/s of steam at 100 kpa and...
Questions
question
Social Studies, 26.02.2021 22:40
question
History, 26.02.2021 22:40
question
Mathematics, 26.02.2021 22:40
question
Social Studies, 26.02.2021 22:40
question
Mathematics, 26.02.2021 22:40
question
Mathematics, 26.02.2021 22:40