subject
Engineering, 06.11.2021 03:50 rocksquad7917

What measures the increase in length relative to the original length stress
strain
tensile strength
compressive strain

ansver
Answers: 3

Another question on Engineering

question
Engineering, 04.07.2019 18:20
Wiy doeres rere okhn a pump whon working betwon the same pressure range?
Answers: 2
question
Engineering, 04.07.2019 19:10
An external consultant recommends that a plant installs a bank of capacitors for power factor correction. this will reduce the peak electrical demand charges by an average of 93 kw every month. the plant current pays $13 per kw in peak demand charges. the capacitor bank will include 223 kw of fixed capacitors, and 183 of variable capacitors. the fixed capacitors cost $59 per kw, and the variable capacitors will cost $65 per kw. the consultant charges 21% of the equipment costs to install the capacitors. because this project will reduce the demand for the electric utility, they are prepared to provide a one-time rebate of $42 per kw of reduced demand. what is the simple payback period for this project (in years)?
Answers: 2
question
Engineering, 06.07.2019 03:10
Tom is having a problem with his washing machine. he notices that the machine vibrates violently at a frequency of 1500 rpm due to an unknown rotating unbalance. the machine is mounted on 4 springs each having a stiffness of 10 kn/m. tom wishes to add an undamped vibration absorber attached by a spring under the machine the machine working frequency ranges between 800 rpm to 2000 rpm and its total mass while loaded is assumed to be 80 kg. a) what should be the mass of the absorber added to the machine so that the natural frequency falls outside the working range? b) after a first trial of an absorber using a mass of 35 kg, the amplitude of the oscillation was found to be 10 cm. what is the value of the rotating unbalance? c) using me-3.5 kg.m, find the optimal absorber (by minimizing its mass). what would be the amplitude of the oscillation of the absorber?
Answers: 1
question
Engineering, 06.07.2019 05:10
An ideal vapor-compression refrigeration cycle is employed to maintain a building temperature of 23°c when the outside temperature is 37°c. the cycle operates at steady state using ammonia as the working fluid. the mass flow rate of the refrigerant is 15 kg/min. the refrigerant enters the compressor at 1.5 bar and 10 °c. the condenser pressure is 20 bar and the temperature at the condenser exit is 45 °c. determine (a) the compressor power in kw. (b) the refrigeration capacity in tons. (c) the coefficient of performance. d) the maximum theoretical coefficient of performance.
Answers: 2
You know the right answer?
What measures the increase in length relative to the original length stress
strain
tensi...
Questions
question
Mathematics, 26.01.2021 17:00
question
Mathematics, 26.01.2021 17:00
question
Mathematics, 26.01.2021 17:00
question
Social Studies, 26.01.2021 17:00