A cascade refrigeration system is used to provide a steady rate (Q1) of low-temperature cooling for a deep freezer maintained at -75°C. Propane is the working fluid for the low-temperature cycle which operates at evaporator and condenser pressures of P1 and P2 respectively. R-134a is the working fluid for the high-temperature cycle which operates at a condenser pressures of P6. Both cycles operate as ideal vapor-compression refrigeration cycles. An intermediate temperature heat exchanger with a 10°C minimum temperature difference between working fluids serves as the evaporator for R-134a and the condenser for propane. Propane System Evaporator Pressure: P1 (bar) = 0.05

Propane System Condenser Pressure: P2 (bar) = 3

R-134a System Condenser Pressure: P6 (bar) = 12

Cooling Capacity: Q1 (kW) = 3.4

Required:

a. Determine the compressor inlet temperature (C) for the propane cycle.

b. Determine the compressor inlet enthalpy (kJ/kg) for

ansver
Answers: 3

Another question on Engineering

question
Engineering, 04.07.2019 19:10
The sum of the normal stresses does not change as the stress state rotates through an angle. a)-trune b)- false
Answers: 2
question
Engineering, 04.07.2019 19:10
A)-in the process of engineering design, explain the contribution of material selection. b)- explain the procedure of synthesis as is employed in engineering design. c)- is there any relationship between ergonomics and engineering design? explain. d)- safety consideration in engineering design includes human, product and the enviroment . explain how safety will be incorporated into the design?
Answers: 3
question
Engineering, 06.07.2019 02:30
In a unit cell of fcc structure, indicate the position of one of the tetrahedral interstitial sites by plotting the corresponding tetrahedron. do the same for one of the octahedral interstitial sites (in a separate fcc unit cell). mark the positions of all the tetrahedral and octahedral interstitial sites in the unit cells. how many equivalent tetrahedral sites and how many equivalent octahedral sites are contained in a fcc unit cell, respectively. what is the coordination number for a tetrahedral site and what is the coordination number for an octahedral site?
Answers: 2
question
Engineering, 06.07.2019 03:10
List and describe the parts of boxford cnc milling machine with pictures?
Answers: 2
You know the right answer?
A cascade refrigeration system is used to provide a steady rate (Q1) of low-temperature cooling for...
Questions
question
Mathematics, 19.02.2021 06:10
question
Mathematics, 19.02.2021 06:10
question
English, 19.02.2021 06:10
question
Chemistry, 19.02.2021 06:10
question
Mathematics, 19.02.2021 06:10
question
Mathematics, 19.02.2021 06:10
question
Mathematics, 19.02.2021 06:10
question
Mathematics, 19.02.2021 06:10
question
Mathematics, 19.02.2021 06:10