subject
Engineering, 29.04.2021 19:00 stephaniem0216

It is desired to produce and aligned carbon fiber-epoxy matrix composite having a longitudinal tensile strength of 600 MPa. Calculate (a) the critical fiber length, and (b) the volume fraction of fibers necessary if (1) the average fiber diameter is 0.028 mm, (2) the average fiber length is 2.2 mm, (3) the fiber fracture strength is 5000 MPa, (4) the fiber-matrix bond strength is 19 MPa, (5) the matrix stress at fiber failure is 16.0 MPa.

ansver
Answers: 2

Another question on Engineering

question
Engineering, 04.07.2019 18:10
For the closed feedwater heater below, feedwater enters state 3 at a pressure of 2000 psia and temperature of 420 °f at a rate of ix10 ibhr. the feedwat extracted steam enters state 1 at a pressure of 1000 psia and enthalpy of 1500 btu/lbm. the extracted er leaves at an enthalpy of 528.7 btu/lbm steam leaves as a saturated liquid. (16) a) determine the mass flow rate of the extraction steam used to heat the feedwater (10) b) determine the terminal temperature difference of the closed feedwater heater
Answers: 3
question
Engineering, 04.07.2019 18:20
Avolume of 2.65 m3 of air in a rigid, insulated container fitted with a paddle wheel is initially at 264 k, 5.6 bar. the air receives 432 kj by work from the paddle wheel. assuming the ideal gas model with cv = 0.71 kj/kg • k, determine for the air the amount of entropy produced, in kj/k
Answers: 2
question
Engineering, 04.07.2019 18:20
Amixture of slurry and mud is to be pumped through a horizontal pipe of diameter 500 mm. the fluid behaves as a bingham plastic with a yield stress of 30 pa and viscosity 0.04 pa.s. describe the effects of the shear stress through a transverse section of the pipe by plotting the variation in shear stress and velocity profile: (i) just before the slurry starts to move (ii) as the slurry flows when the pressure gradient is double that in part (i)
Answers: 3
question
Engineering, 04.07.2019 19:10
What is the chief metrological difference between measuring with a microscope and with an electronic comparator? a. the microscope is limited to small workpieces.a. the microscope is limited to small workpieces. c. the comparator can only examine one point on the workpiece. d. the microscope carries its own standard.
Answers: 1
You know the right answer?
It is desired to produce and aligned carbon fiber-epoxy matrix composite having a longitudinal tensi...
Questions
question
English, 15.01.2021 01:00
question
English, 15.01.2021 01:00
question
Mathematics, 15.01.2021 01:00
question
Mathematics, 15.01.2021 01:00
question
Mathematics, 15.01.2021 01:00
question
Mathematics, 15.01.2021 01:00