subject
Engineering, 10.04.2021 15:40 GingerSnaps

Queremos construir un horno de ladrillo refractario con 6 pulgadas de espesor, con una conductividad térmica de 0.93 joules/pies-seg-°F reforzado con miembros de acero al carbón dentro del ladrillo, el área total de la sección transversal del mismo es equivalente al 2,25% del área interior de la pared del horno. Si la conductividad térmica del acero de refuerzo es de 75 joules/pies-seg-°F calcular lo siguiente: a) Las relaciones proporcionales del calor total transferido a través de la pared por el ladrillo y por el acero al carbón, b) la pérdida de calor por cada metro cuadrado de la pared si el lado interior de la pared está a 350°F y el lado exterior está a 85°F

ansver
Answers: 2

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Apump is used to circulate hot water in a home heating system. water enters the well-insulated pump operating at steady state at a rate of 0.42 gal/min. the inlet pressure and temperature are 14.7 lbf/in.2, and 180°f, respectively; at the exit the pressure is 60 lbf/in.2 the pump requires 1/15 hp of power input. water can be modeled as an incompressible substance with constant density of 60.58 lb/ft3 and constant specific heat of 1 btu/lb or. neglecting kinetic and potential energy effects, determine the temperature change, in °r, as the water flows through the pump.
Answers: 1
question
Engineering, 04.07.2019 18:10
Which from the following instrument is commonly used to detect the high pitch butzing sound in bearings? [clo4] a)-digital ultrasonic meter b)-infrared camera c)-spectroscopic d)-vibrometer
Answers: 2
question
Engineering, 04.07.2019 18:10
An air compression refrigeration system is to have an air pressure of 100 psia in the brine tank and an allowable air temperature increase of 60°f for standard vapor compression cycle temperatures of 77 f entering the expansion cylinder and 14 f entering the compression cylinder, calculate the coefficient of performance a. 2.5 b 3.3 c. 4.0 d. 5.0
Answers: 3
question
Engineering, 04.07.2019 18:20
Most leaks in reciprocating air compressors can be detected and minimized by: (clo4) a)-detecting leakage areas using ultrasonic acoustic detector. b)-tightening joints and connections c)-replacing faulty equipment d)-all of the given options
Answers: 2
You know the right answer?
Queremos construir un horno de ladrillo refractario con 6 pulgadas de espesor, con una conductividad...
Questions
question
History, 10.12.2021 01:00
question
Mathematics, 10.12.2021 01:00
question
Mathematics, 10.12.2021 01:00