Calculate the weight of each of the slabs based on the following data: The project is a 574 m2 building for the use of operations offices for the ArTech company. The building consists of a ground floor (Level +0.0), a mezzanine level (Level +3.0 m) and a roof terrace (Level +6.0 m). The construction system consists of a reinforced concrete structure. Figure 1 (a) shows the architectural plan of Level +0.0, Figure 1 (b) the level +3.0 m and Figure 1 (c) the level +6.0 m. The spaces are delimited with dividing walls with a partition or table-rock system, see Figure 2. (Figure 1 Architectural plan: (a) Ground floor, (b) Mezzanine level, (c) Roof )

Materials: Concrete is considered to be M28 (28 MPa) and reinforcing steel is G42 (414 MPa). Consider that the rods on the market are: # 3, # 4, # 5, # 6 and # 8.
Loads: The loads to consider are dead and alive. The magnitudes of the loads must satisfy the requirements of the Construction Regulations for the Federal District. Consider that the electrical, lighting, hydraulic, sanitary and air conditioning installations are typical for an office building. The floor consists of 10 mm thick ceramic pieces (density = 17 kN / m3) and a 3 mm floor glue (density = 14 kN / m3). The facade walls are hollow pieces of mortar.
Structural system: The floor system consists of ribbed slabs in two directions perimeter supported on beams to form reinforced concrete frames. The total depth of the slabs is 25 cm, with 15 cm wide ribs and a 5 cm compression layer. The lightener are removable 60x60 cm. The upper part of the beams is embedded in the slab making a monolithic casting.


Calculate the weight of each of the slabs based on the following data:

The project is a 574 m2 bu
Calculate the weight of each of the slabs based on the following data:

The project is a 574 m2 bu
Calculate the weight of each of the slabs based on the following data:

The project is a 574 m2 bu

ansver
Answers: 1

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Air is to be cooled in the evaporator section of a refrigerator by passing it over a bank of 0.8-cm-outer-diameter and 0.4-m-long tubes inside which the refrigerant is evaporating at -20°c. air approaches the tube bank in the normal direction at 0°c and 1 atm with a mean velocity of 4 m/s. the tubes are arranged in-line with longitudinal and transverse pitches of sl- st 1.5 cm. there are 30 rows in the flow direction with 15 tubes in each row. determine (a) the refrigeration capacity of this system and (b) pressure drop across the tube bank. evaluate the air properties at an assumed mean temperature of -5°c and 1 atm. is this a good assumption?
Answers: 1
question
Engineering, 04.07.2019 18:10
Slip occurs via two partial dislocations because of (a) the shorter path of the partial dislocation lines; (b) the lower energy state through partial dislocations; (c) the charge balance.
Answers: 1
question
Engineering, 04.07.2019 18:10
The higher the astm grain size number, the finer the gran is. a)-true b)-false
Answers: 2
question
Engineering, 04.07.2019 18:20
Most leaks in reciprocating air compressors can be detected and minimized by: (clo4) a)-detecting leakage areas using ultrasonic acoustic detector. b)-tightening joints and connections c)-replacing faulty equipment d)-all of the given options
Answers: 2
You know the right answer?
Calculate the weight of each of the slabs based on the following data: The project is a 574 m2 buil...
Questions
question
Chemistry, 12.02.2021 17:20
question
Mathematics, 12.02.2021 17:20
question
English, 12.02.2021 17:20
question
Mathematics, 12.02.2021 17:20
question
Mathematics, 12.02.2021 17:20