subject
Engineering, 14.01.2021 15:00 dontcareanyonemo

Equilateral triangular sewer, 1.5 m on each side, constructed of concrete, used to drain at a flow rate of 1000 kg / m 5, with the effluent density of 1100 kg / m and viscosity of 1.25 cP, length 10. km before entering the center. Calculate 1.1 The area of contact with the sewage of the pipe (Perimeter of pipe, P) is equal to how many meters?
1.2 The cross-sectional area of the sewer. (Goss-sectional are, A) is how many square meters?
1.3 What is the hydraulic radius, R. Since the in-pipe flow (h) is equal to the water meter when calculated with the Hazen Williams Formula, it has a Hazen-Williams constant of 110 1.6 What is the system pressure drop in kPa 1.7 The power of the pump at How many watts must be compensated for the system when the pump efficiency is 0.85 1.8 Reynolds number of particles?

ansver
Answers: 2

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Coiled springs ought to be very strong and stiff. si3n4 is a strong, stiff material. would you select this material for a spring? explain.
Answers: 2
question
Engineering, 04.07.2019 18:20
Have a greater impact on maintenance productivity than any other support group. (clo5) a)-the top management b)-inventory and purchasing c)-sub-contracting d)-cmms
Answers: 2
question
Engineering, 04.07.2019 18:20
Athin walled concentric tube exchanger is used to cool engine oil from 160°c to 60°c with water that is available at 25°c acting as a coolant. the oil and water flow rates are each at 2 kg/s, and the diameter of the inner tube is 0.5 m and the corresponding value of the overall heat transfer coefficient is 250 w/m2. oc. how long must the heat exchanger be to accomplish the desired cooling? cpwater=4.187 kj/kg-candcpengine el=2.035 kj/kg·°c, oil . 120]
Answers: 1
question
Engineering, 04.07.2019 18:20
Along 8-cm diameter steam pipe whose external surface temperature is 900c connects two buildings. the pipe is exposed to ambient air at 70c with a wind speed of 50 km/hr blowing across the pipe. determine the heat loss from the pipe per unit length. (b) air at 500c enters a section of a rectangular duct (15 cm x 20 cm) at an average velocity of 7 m/s. if the walls of the duct are maintained at 100c. a) the length of the tube for an exit temperature of the air to be 40 0c. b)the rate of heat transfer from the air. c) the fan power needed to overcome the pressure drop in this section of the duct.
Answers: 1
You know the right answer?
Equilateral triangular sewer, 1.5 m on each side, constructed of concrete, used to drain at a flow r...
Questions
question
Mathematics, 24.03.2020 03:57
question
Mathematics, 24.03.2020 03:57
question
English, 24.03.2020 03:58
question
History, 24.03.2020 03:58
question
Mathematics, 24.03.2020 03:59
question
Mathematics, 24.03.2020 03:59