While the outdoor temperature of a house is 47C, a cooling machine is used to keep a constant temperature of 27C. The total cooling load of the house is 15 kW. The power (electrical power) required for the cooling machine of the unit comes from a reversible heat engine operating between 427 source, 47 ℃ well temperatures. According to the heat of the reversible heat machine at 47 ° C we received 10 kW of heat, a) Thermal power delivered by the cooling wash to the outside environment,
b) COP value of laundering, c) If the cooling machine is also reversible, what is the calculation of the maximum heat it can absorb from the house

ansver
Answers: 1

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Courses that are developed by subject matter experts, internal or extemal to the college or university. these programs are marketed by the school (clo2) marks a)-vocational schools b)-vendor training c)-colleges & universities d)-continuing education programs
Answers: 2
question
Engineering, 04.07.2019 19:10
The maximum shear stress and maximum flexural stress occur at the same location along a beam subjected to a non-uniform bending load. a)-trune b)- false
Answers: 2
question
Engineering, 04.07.2019 19:20
Liquid flows at steady state at a rate of 2 lb/'s through a pump, which operates to raise the elevation of the liquid 100 ft from control volume inlet to exit. the liquid specific enthalpy at the inlet is 40.09 btu/lb and at the exit is 40.94 btub. the pump requires 3 btu/s of power to operate. if kinetic energy effects are negligible and gravitational acceleration is 32.174 tt/s, the heat transfer rate associated with this steady state process is most closely 1)-2,02 btu/s from the liquid to the surroundings 2)-3.98 btu/s from the surroundings to the liquid. 3)-4.96 btu/s from the surroundings to the liquid. 4)-1.04 btu/s from the liquid to the surroundings.
Answers: 2
question
Engineering, 04.07.2019 19:20
Air enters a horizontal, constant-diameter heating duct operating at steady state at 290 k, 1 bar, with a volumetric flow rate of 0.25 m°/s, and exits at 325 k, 0.95 bar. the flow area is 0.04 m2. assuming the ideal gas model with k = 1.4 for the air, determine (a) the velocity at the inlet and exit, each in m/s, and (c) the rate of heat transfer, in kw flow rate, in kg/s, (b) the mass kg 0.3
Answers: 2
You know the right answer?
While the outdoor temperature of a house is 47C, a cooling machine is used to keep a constant temper...
Questions
question
Mathematics, 27.04.2021 17:30
question
English, 27.04.2021 17:30
question
Mathematics, 27.04.2021 17:30
question
Mathematics, 27.04.2021 17:30
question
Mathematics, 27.04.2021 17:30
question
Mathematics, 27.04.2021 17:30