Fluke
match the specification type on the left by
dragging its purpose on the right. do this...
Engineering, 08.12.2020 01:50 RebeccaBloop8578
Fluke
match the specification type on the left by
dragging its purpose on the right. do this for each
specification type
maximum measurements
calculate measurement error
safety ratings
· reduce electrical hazards
digits and counts
determine largest and smallest
number on the display
accuracy
tolerance for rough service
operating temperatures
electrical limitations
physical shock and vibration
environmental conditions
Answers: 2
Engineering, 04.07.2019 18:10
Air is to be cooled in the evaporator section of a refrigerator by passing it over a bank of 0.8-cm-outer-diameter and 0.4-m-long tubes inside which the refrigerant is evaporating at -20°c. air approaches the tube bank in the normal direction at 0°c and 1 atm with a mean velocity of 4 m/s. the tubes are arranged in-line with longitudinal and transverse pitches of sl- st 1.5 cm. there are 30 rows in the flow direction with 15 tubes in each row. determine (a) the refrigeration capacity of this system and (b) pressure drop across the tube bank. evaluate the air properties at an assumed mean temperature of -5°c and 1 atm. is this a good assumption?
Answers: 1
Engineering, 04.07.2019 18:10
Ahot wire operates at a temperature of 200°c while the air temperature is 20°c. the hot wire element is a tungsten wire of 5 um diameter and 2 mm in length. plot using excel current, heat transfer and heat generated by the wire for air velocity varying from 1-10 m/s in steps of lm/s? matlab the sensor voltage output, resistance, or assume nu 0.989 re033pr13 take air properties at tr (200°c20°c)/2 = 110°c properties of tungsten: c 0.13 kj/kg.k 3 p 19250 kg/m k (thermal conductivity) = 174 w/m.k
Answers: 2
Engineering, 04.07.2019 18:20
Ahe-xe mixture containing a 0.75 mole fraction of helium is used for cooling electronics in an avionics application. at a temperature of 300 k and atmospheric pressure, calculate the mass fraction of helium and the mass density, molar concentration and molecular weight of the mixture. if the cooling capacity is 10 l, what is the mass of the coolant?
Answers: 3
Engineering, 04.07.2019 18:20
How much power could a wind turbine produce if it had the following specifications? cp = 0.45 -d=1.2kg/m3 d=50m v 5m/s
Answers: 2
Physics, 27.05.2020 19:08
Mathematics, 27.05.2020 19:08
Mathematics, 27.05.2020 19:08
Mathematics, 27.05.2020 19:08
Mathematics, 27.05.2020 19:08
Mathematics, 27.05.2020 19:08
Mathematics, 27.05.2020 19:08
Mathematics, 27.05.2020 19:08
Mathematics, 27.05.2020 19:08
History, 27.05.2020 19:08
History, 27.05.2020 19:08