Suppose a utility company is selling electric power for $0.03/kWh at night and is willing to pay $0.08/kWh for power produced during the day. To take advantage of this opportunity, an entrepreneur is considering building a large reservoir 40 m above the lake level, pumping water from the lake to the reservoir at night using cheap power, and letting the water flow from the reservoir back to the lake during the day, producing power as the pump–motor operates as a turbine– generator during reverse flow. Preliminary analysis shows that a water flow rate of 2 m3 /s can be used in either direction, and the irreversible head loss of the piping system is 4 m. The combined pump–motor and turbine–generator efficiencies are expected to be 75 percent each. Assuming the system operates for 10 h each in the pump and turbine modes during a typical day, determine the potential revenue this pump–turbine system can generate per year.

ansver
Answers: 1

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Manometers are good examples of measuring instruments, nowadays they are not as common as before. a)-capacitive probe gauges b)-gravitational gauges deformation ) gauges d)-digital gauges
Answers: 1
question
Engineering, 04.07.2019 19:10
An external consultant recommends that a plant installs a bank of capacitors for power factor correction. this will reduce the peak electrical demand charges by an average of 93 kw every month. the plant current pays $13 per kw in peak demand charges. the capacitor bank will include 223 kw of fixed capacitors, and 183 of variable capacitors. the fixed capacitors cost $59 per kw, and the variable capacitors will cost $65 per kw. the consultant charges 21% of the equipment costs to install the capacitors. because this project will reduce the demand for the electric utility, they are prepared to provide a one-time rebate of $42 per kw of reduced demand. what is the simple payback period for this project (in years)?
Answers: 2
question
Engineering, 05.07.2019 19:10
Tech a says never use a water hose to clean up dust after a repair. tech b says never use a floor scrubber to clean up dust after repairs. who is correct?
Answers: 1
question
Engineering, 06.07.2019 04:30
State two advantages and two disadvantages of interchangeability.
Answers: 3
You know the right answer?
Suppose a utility company is selling electric power for $0.03/kWh at night and is willing to pay $0....
Questions
question
Mathematics, 17.06.2020 13:57
question
Mathematics, 17.06.2020 13:57
question
Biology, 17.06.2020 13:57
question
Mathematics, 17.06.2020 13:57
question
Mathematics, 17.06.2020 13:57
question
Mathematics, 17.06.2020 13:57
question
Mathematics, 17.06.2020 13:57