A syringe pump is often used to pump small precise volumes of liquids. Imagine you are given a faulty syringe pump to use in the lab. The pump leaks at a rate of 15% whatever the flowrate out of the nozzle Qn. The syringe has a diameter (Ds) of 30 mm, a length of 120 mm and a nozzle diameter (Dn) of 3 mm. For your experiment, a nozzle flowrate of 1 milliliters/s is required. Answer the following questions: (a) At what rate do you need to program the plunger velocity (Vp) to ensure you achieve the targeted flowrate (in mm/s)?
(b) How long will you be able to maintain this flowrate (in min)?

ansver
Answers: 2

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Apipe with an outside diameter of 15 cm is exposed to an ambient air and surrounding temperature of -20°c. the pipe has an outer surface temperature of 65°c and an emissivity of 0.85. if the rate of heat loss from the pipe surface is 0.95 kw per meter of length, the external convective heat transfer coefficient (h) is: (a) 12.5 w/m"k (b) 18.6 w/mk (c) 23.7 w/mk (d) 27.9 w/mk (e) 33.5 w/mk
Answers: 1
question
Engineering, 04.07.2019 18:10
Machinery that is a key part of the process and without which the plant or process cannot function is classifed as: (clo4) a)-critical machinery b)-essential machinery c)-general purpose machinery d)-none of the specified options.
Answers: 1
question
Engineering, 04.07.2019 18:20
Refrigerant-134a enters the compressor of a refrigerator as superheated vapor at 0.14 mpa and -10°c at a rate of 0.05 ka/s and leaves at 0.8 mpa and 50°c. the refrigerant is cooied in the condenser to 0.72 mpa and 26'c. it is then throttled to 0.15 mpa. sketch the t-s diagram for the system and evaluate: 6) the rate of heat removai from the refrigerated space (kw), it) the power input to the compressor (kw), ii) the isentropic efficiency of the compressor (%), and iv) the cop of the refrigerator.
Answers: 2
question
Engineering, 04.07.2019 18:20
Aheavily insulated piston-cylinder device contains 0.02 m3 of steam at 300 kpa and 200 °c. 1.2 mpa. d this process. team is now compressed in a reversible manner to a pressure of etermine the entropy change and the work done on the steam during this process
Answers: 1
You know the right answer?
A syringe pump is often used to pump small precise volumes of liquids. Imagine you are given a fault...
Questions
question
Mathematics, 20.09.2020 14:01
question
Computers and Technology, 20.09.2020 14:01
question
Mathematics, 20.09.2020 14:01
question
Computers and Technology, 20.09.2020 14:01