subject
Engineering, 23.07.2020 03:01 kharmaculpepper

Catalogue data for a six-cylinder refrigerant 22 compressor operating at 29 r/s (revolution per second) indicates a refrigerating capacity of 96.4 kW and a power requirement of 28.9 kW at an evaporating temperature of 5°C and condensing temperature of 50°C. The performance data are based on 3°C liquid sub-cooling and 8°C super-heating of suction gas entering the compressor. The cylinder bore (diameter) is 67mm and piston stoke is 57mm. Compute: (a) The clearance volumetric efficiency if the clearance volume is 4.8% (b) The actual volumetric efficiency (c) Compression efficiency 1.

ansver
Answers: 2

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Apump is used to circulate hot water in a home heating system. water enters the well-insulated pump operating at steady state at a rate of 0.42 gal/min. the inlet pressure and temperature are 14.7 lbf/in.2, and 180°f, respectively; at the exit the pressure is 60 lbf/in.2 the pump requires 1/15 hp of power input. water can be modeled as an incompressible substance with constant density of 60.58 lb/ft3 and constant specific heat of 1 btu/lb or. neglecting kinetic and potential energy effects, determine the temperature change, in °r, as the water flows through the pump.
Answers: 1
question
Engineering, 04.07.2019 18:10
Asingle-geared blanking press has a stroke of 200 mm and a rated capacity of 320 kn. a cam driven ram is assumed to be capable of delivering the full press load at constant force during the last 15 percent of a constant-velocity stroke. the camshaft has an average speed of 90 rev/min and is geared to the flywheel shaft at a 6: 1 ratio. the total work done is to include an allowance of 16 percent for friction a) estimate the maximum energy fluctuation b) find the rim weight for an effective diameter of 1.2 m and a coefficient of speed fluctuation of 0.10
Answers: 1
question
Engineering, 04.07.2019 19:10
Estimate the change in specific internal energy au and specific enthalpy h from inlet to outlet for ethylene glycol (a liquid) flowing through each of the following devices: (a) a heat exchanger where the glycol temperature increases from 20 °c to 80 °c; (b) a pump operating at about 25 °c and increasing the glycol pressure from 100 kpa to 8 mpa.
Answers: 2
question
Engineering, 04.07.2019 19:20
Apiping systems consists of 6 m of 6-std type k and 12 m of 4-std type k, both drawn copper tubing. the system conveys ethylene glycol at a rate of 0.013 m3/s. the pressure drop across the system is to be calculated. there are two 90° elbows in the 6-in pipe, a reduction from the 6-in pipe to the 4-in pipe and four 90° elbows in the 4-in pipe. all fittings are soldered (same as flanged) and regular. the inlet and outlet of the system are at the same height.
Answers: 1
You know the right answer?
Catalogue data for a six-cylinder refrigerant 22 compressor operating at 29 r/s (revolution per seco...
Questions
question
Chemistry, 18.04.2020 11:10
question
Mathematics, 18.04.2020 11:26
question
Biology, 18.04.2020 11:27
question
History, 18.04.2020 11:27