subject
Engineering, 24.06.2020 21:01 ladybug9014

What are you expect to learn in ECONMT 100: Safety Standards and Construction Industry?

ansver
Answers: 1

Another question on Engineering

question
Engineering, 04.07.2019 19:10
An external consultant recommends that a plant installs a bank of capacitors for power factor correction. this will reduce the peak electrical demand charges by an average of 93 kw every month. the plant current pays $13 per kw in peak demand charges. the capacitor bank will include 223 kw of fixed capacitors, and 183 of variable capacitors. the fixed capacitors cost $59 per kw, and the variable capacitors will cost $65 per kw. the consultant charges 21% of the equipment costs to install the capacitors. because this project will reduce the demand for the electric utility, they are prepared to provide a one-time rebate of $42 per kw of reduced demand. what is the simple payback period for this project (in years)?
Answers: 2
question
Engineering, 04.07.2019 19:20
Acarnot refrigerator operates in a room in which the temperature is 21°c and of power when operating. if the food compartment of the refrigerator is consumes 3 kw to be maintained at 2°c, determine (a) the coefficient of performance of the cycle and (b) the rate of heat removal from the food compartment. refrigerator cycle that has a higher coefficient of performance than that of the discussed (e) is it possible to develop a carn ot refrigerator, operating between the same temperature limits? explain
Answers: 2
question
Engineering, 06.07.2019 02:30
1in2 processor chip can be modelled as an isothermal plane wall of silicon, isothermal on both sides. the power input to the bottom of the plane wall, or the processing power of the chip, often called the thermal design power (tdp), is 100w. assume the periphery is adiabatic. the silicon is 400 microns thick. the temperature at the junction, or in this case on the bottom of the isothermal plane wall, is 85°c. what is the top surface temperature, assuming that the only mode of heat transfer is conduction
Answers: 1
question
Engineering, 06.07.2019 03:20
An air-conditioning system consists of a heating section and an evaporative cooler. air enters the heating section at 10°c and 70 percent relative humidity at a rate of 30m^3/min, and it leaves the evaporative cooler at 20°c and 60 percent relatively humidity. if the air conditioning system operates at a total pressure of 98 kpa, determine (a) the temperature and relative humidity of the air when it leaves the heating section, (b) the rate of heat transfer in the heating section, and (c) the rate of water added to air in the evaporative cooler
Answers: 2
You know the right answer?
What are you expect to learn in ECONMT 100: Safety Standards and Construction Industry?...
Questions