A cylindrical tank needs to be designed which will hold 2 m3 of liquid. The tank is to be made of areinforced plastic material that is 1 cm thick and has a thermal conductivity of 0.8 W/m·K. The sides of the tank are further insulated with a foam of thickness 2 cm with thermal conductivity of 0.2 W/m·K. The top and bottom of the tank are not insulated. The tank rests on ground which is always at 20oC. The air around the tank is at 10oC and provides a convective heat transfer coefficient of 15 W/m2·K. The liquid in the tank must be kept at a temperature of 50oC by a heater. The liquid is stirred so it is all at the same temperature, and the resulting heat transfer coefficient on the inner surface of the tank is 200 W/m2·K. Radiation from the tank can be neglected.

a.)What inner diameter, D, and height, H, should be chosen for the tank to minimize the amount of power required for heating?
b.)What is the required heating power with these ideal dimensions?
c.)What is the temperature at the interface between the insulation and tank wall for this condition?

ansver
Answers: 2

Another question on Engineering

question
Engineering, 03.07.2019 19:30
When using the ohmmeter function of a digital multimeter, the leads are placed in what position relative to the component being tested? a. parallel b. control c. series d. line
Answers: 3
question
Engineering, 04.07.2019 18:10
Water at the rate of 1 kg/s is forced through a tube with a 2.5 cm inner diameter. the inlet water temperature is 15°c, and the outlet water temperature is 50°c. the tube wall temperature is 14°c higher than the local water temperature all along the length of the tube. what is the length of the tube?
Answers: 3
question
Engineering, 04.07.2019 19:20
Aseries piping system conveys methyl alcohol. the system consists of 70 m of 1- nominal pipe follow by 50 m of 2-nominal pipe, both schedule 40 commercial steel. the 1-nominal pipe contains 3 90° elbows (regular) anda fully open gate valve, all threaded. the pressure drop through the system is 150 kpa. determine the volume flow rate through the system that is horizontally laid.
Answers: 1
question
Engineering, 04.07.2019 19:20
Air at a pressure of 1atm and a temperature of 40 c is in parallel flow over the top surface of a flat plate that is heated to a uniform temperature of 120 c. the plate has a length of 0.40m (in the flow direction) and a width of 0.15m. the reynolds number based on the plate length is 50, 000. what is the rate of heat transfer from the plate to the air? if the free stream velocity of the air is doubled and the pressure is increased to 10 atm what is the rate of heat transfer?
Answers: 2
You know the right answer?
A cylindrical tank needs to be designed which will hold 2 m3 of liquid. The tank is to be made of ar...