A double-pipe heat exchanger is used to cool a hot fluid (cp = 3800 J/kg·K) entering the heat exchanger at 200°C with a flow rate of 0.4 kg/s. In the cold side, cooling fluid (cp = 4200 J/kg·K) enters the heat exchanger at 10°C with a mass flow rate of 0.5 kg/s. The double-pipe heat exchanger has a thin-walled inner tube, with convection heat transfer coefficients inside and outside of the inner tube estimated to be 1400 W/m2 ·K and 1100 W/m2 ·K, respectively. The heat exchanger has a heat transfer surface area of 2.5 m2 , and the estimated fouling factor caused by the accumulation of deposit on the surfaces is 0.0002 m2 ·K/W. (a) Determine the effectiveness values for the parallel- and counter-flow configurations. (b) Determine outlet temperatures of the hot fluid for the parallel- and counter-flow configurations. (c) Determine outlet temperatures of the cold fluid for the parallel- and counter-flow configurations.

ansver
Answers: 2

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Acompressor receives the shaft work to decrease the pressure of the fluid. a)- true b)- false
Answers: 3
question
Engineering, 04.07.2019 18:20
Air flows over a heated plate àt a velocity of 50m/s. the local skin factor coefficient at a point on a plate is 0.004. estimate the local heat transfer coefficient at this point.the following property data for air are given: density = 0.88kg/m3 , viscosity 2.286 x 10 ^-5 kgm/s , k = 0.035w/mk ,cp = 1.001kj/kgk. use colburn reynolds analogy.
Answers: 1
question
Engineering, 04.07.2019 19:20
Apreheater involves the use of condensing steam at 100°c on the inside of a bank of tubes to heat air that enters at 1 atm and 25°c. the air moves at 5 m/s in cross flow over the tubes. each tube is 1 m long and has an outside diameter of 10 mm. what is the minimum value of nl needed to achieve an outlet temperature of t 75 c? what is the corresponding pressure drop across the tube bank?
Answers: 3
question
Engineering, 06.07.2019 04:10
Aheat pump with refrigerant-134a as the working fluid is used to keep a space at 25°c by absorbing heat from geothermal water that enters the evaporator at 500c at a rate of 0.065 kg/s and leaves at 40°c. the refrigerant enters the evaporator at 20°c with a quality of 23 percent and leaves at the inlet pressure as saturated vapor. the refrigerant loses 300 w of heat to the surroundings as it flows through the compressor and the refrigerant leaves the compressor at 1.4 mpa at the same entropy as the inlet. determine: (a) the degrees of subcooling of the refrigerant in the condenser, b)-the mass flow rate of the refrigerant . (c) the heating load and the cop of the pump, and d)-the theoretical minimum power input to the compressor for the same heating load.
Answers: 3
You know the right answer?
A double-pipe heat exchanger is used to cool a hot fluid (cp = 3800 J/kg·K) entering the heat exchan...