subject
Engineering, 10.04.2020 22:57 Nyasiabaltimore3

Forced air at 25C and 10m/s is used to cool chips on a circuit board. Consider a chip, 4mm x 4mm, located 120mm from the leading edge of the board. An empirical correlation has been established for the local Nusselt number:

Nu_x = 0.04 * Re_x^0.85 * Pr^(1/3)

Estimate the surface temperature of the chip if it is dissipating 30mW.

(Thermophysical properties of air at 25C are needed to solve this problem. Please state your reference source for this information.)

ansver
Answers: 3

Another question on Engineering

question
Engineering, 04.07.2019 18:10
An air conditioning system consist of a 5 cm diameter pipe, operating at a pressure of 200 kpa. the air initially enters the pipe at 15°c with a velocity of 20 m/s and relative humidity of 80%. if the heat supply throughout the process is 960 w, determine the relative humidity and the temperature at the outlet
Answers: 3
question
Engineering, 04.07.2019 18:10
Ariver flows from north to south at 8 km/h. a boat is to cross this river from west to east at a speed of 20 km/h (speed of the boat with respect to the earth/ground). at what angle (in degrees) must the boat be pointed upstream such that it will proceed directly across the river (hint: find the speed of the boat with respect to water/river)? a 288 b. 21.8 c. 326 d. 30.2
Answers: 3
question
Engineering, 04.07.2019 18:10
A-mn has a cubic structure with a0 0.8931 nm and a density of 7.47 g/cm3. b-mn has a different cubic structure, with a0 0.6326 nm and a density of 7.26 g/cm3. the atomic weight of manganese is 54.938 g/mol and the atomic radius is 0.112 nm. determine the percent volume change that would occur if a-mn transforms to b-mn.
Answers: 2
question
Engineering, 04.07.2019 18:20
Athin walled concentric tube exchanger is used to cool engine oil from 160°c to 60°c with water that is available at 25°c acting as a coolant. the oil and water flow rates are each at 2 kg/s, and the diameter of the inner tube is 0.5 m and the corresponding value of the overall heat transfer coefficient is 250 w/m2. oc. how long must the heat exchanger be to accomplish the desired cooling? cpwater=4.187 kj/kg-candcpengine el=2.035 kj/kg·°c, oil . 120]
Answers: 1
You know the right answer?
Forced air at 25C and 10m/s is used to cool chips on a circuit board. Consider a chip, 4mm x 4mm, lo...
Questions
question
Social Studies, 15.12.2020 16:30
question
Mathematics, 15.12.2020 16:30
question
English, 15.12.2020 16:30