subject
Engineering, 04.04.2020 10:29 Angela1998

An activated sludge plant receive 5.0 MGD of wastewater with a BOD of 220 mg/L. The primary clarifier removes 35% of the BOD. The sludge is aerated for 6 hr. The food-to-microorganism ratio is 0.30. The recirculation ratio is 0.2. The surface loading rate of the secondary clarifier is 800 gal/day-ft2. The final effluent has a BOD of 15 mg/L. What are the (a) BOD removal efficiency of the activated sludge treatment processes (secondary BOD removal), (b) aeration tank volume, (c) MLSS, and (d) secondary clarifier surface area? If 0.5 pound of oxygen is required for each pound of BOD entering the aeration tank and the density of air is approximately 0.075 lb/ft3, and the air is 20.9% oxygen by volume, calculate air requirements per day.

ansver
Answers: 2

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Consider a large isothermal enclosure that is maintained at a uniform temperature of 2000 k. calculate the emissive power of the radiation that emerges from a small aperture on the enclosure surface. what is the wavelength ? , below which 10% of the emission is concentrated? what is the wavelength ? 2 above which 10% of the emission is concentrated? determine the wavelength at which maximum spectral emissive power occurs. what is the irradiation incident on a small object placed inside the enclosure?
Answers: 2
question
Engineering, 04.07.2019 18:10
What are the two (02) benefits, which may result from a successful implementation of preventive maintenance (pm) program in an organization? (clo3)a)- lean manufacturing b)-overlapping responsibilities c)-the planner is not qualified d)-accurate contractor information e)-reduction in equipment redundancies f)-accurate stores information
Answers: 3
question
Engineering, 04.07.2019 18:20
Air is compressed isentropically from an initial state of 300 k and 101 kpa to a final temperature of 1000 k. determine the final pressure using the following approaches: (a) approximate analysis (using properties at the average temperature) (b) exact analysis
Answers: 1
question
Engineering, 04.07.2019 18:20
Find the kinematic pressure of 160kpa. for air, r-287 j/ kg k. and hair al viscosity of air at a temperature of 50°c and an absolute (10 points) (b) find the dynamic viscosity of air at 110 °c. sutherland constant for air is 111k
Answers: 3
You know the right answer?
An activated sludge plant receive 5.0 MGD of wastewater with a BOD of 220 mg/L. The primary clarifie...
Questions
question
Mathematics, 13.09.2021 05:10
question
Health, 13.09.2021 05:10
question
Mathematics, 13.09.2021 05:10