subject
Engineering, 11.03.2020 04:26 keithlavender123

An ideal vapor-compression heat pump cycle using R-134a is used to heat a house. The insidetemperature is 22°C, the outside temperature is 0°C. Saturated vapor at 2.2 bar enters thecompressor, saturated liquid leaves the condenser at 8 bar. The mass flow rate is 0.2 kg/s.
Calculate:
(a) the power input to the compressor, in kW.
(b) the coefficient of performance.

ansver
Answers: 3

Another question on Engineering

question
Engineering, 03.07.2019 15:10
Heat is added to a piston-cylinder device filled with 2 kg of air to raise its temperature 400 c from an initial temperature of t1 27 cand pressure of pi 1 mpa. the process is isobaric process. find a)-the final pressure p2 b)-the heat transfer to the air.
Answers: 1
question
Engineering, 04.07.2019 18:20
Acertain flow of air (at stp) has a velocity distribution given by v i (in ft/s). if this flow is going through a 4 ft square area in the yz-plane (centered at the origin), what is the mass flow rate (in lbm/s)?
Answers: 2
question
Engineering, 04.07.2019 19:20
Amass-spring-viscous damper system of mass 3 kg has a frequency of 100 rad/s and is critically damped. its initial conditions are x(0)-3 mm and (0)-2.3 m/s. does the system overshoot its equilibrium position? prove your answer
Answers: 1
question
Engineering, 06.07.2019 03:10
Tom is having a problem with his washing machine. he notices that the machine vibrates violently at a frequency of 1500 rpm due to an unknown rotating unbalance. the machine is mounted on 4 springs each having a stiffness of 10 kn/m. tom wishes to add an undamped vibration absorber attached by a spring under the machine the machine working frequency ranges between 800 rpm to 2000 rpm and its total mass while loaded is assumed to be 80 kg. a) what should be the mass of the absorber added to the machine so that the natural frequency falls outside the working range? b) after a first trial of an absorber using a mass of 35 kg, the amplitude of the oscillation was found to be 10 cm. what is the value of the rotating unbalance? c) using me-3.5 kg.m, find the optimal absorber (by minimizing its mass). what would be the amplitude of the oscillation of the absorber?
Answers: 1
You know the right answer?
An ideal vapor-compression heat pump cycle using R-134a is used to heat a house. The insidetemperatu...
Questions
question
Mathematics, 12.10.2020 21:01
question
Mathematics, 12.10.2020 21:01
question
Mathematics, 12.10.2020 21:01
question
Chemistry, 12.10.2020 21:01
question
Biology, 12.10.2020 21:01
question
Mathematics, 12.10.2020 21:01