The data for characteristic curves of a variable-speed pump supplied by a manufacturer are given below. Draw the modified curve and H-Q curve for two pumps operating in parallel. Also draw the system head curves. Use the following data:

Piping, valves, fitting, and specials from wet well to common header are given bellow:

Pipe size= 46 cm
Pipe straight length is short and negligible
Two 46-cm gate valves, K= 0.19
One 46-cm 90∘elbows, K= 0.30
Two 46-cm to 31 cm reducers, K= 0.25
One 46-cm check valve, K=2.5
One 46-cm tee, K=1.80
One 62-cm entrance suction bell, K= 0.04

Piping, valves, fitting, and specials from common header to discharge are given bellow:

Pipe size= 76 cm
Pipe straight length= 65 m, C= 100
Two 76-cm 90∘elbows, K= 0.30
Two 76-cm 45∘elbows, K= 0.20
One Venturi meter with throat diameter of 38 cm, k= 0.14
One 76-cm plug valve, K= 1.00
One 76-cm Wye branch, K= 1.38
The pump volute elevation is 300.00 m. Maximum and minimum water surface elevation in the wet well are 303.00 and 301.00 m, respectively. The water surface elevation in the discharge unit is 315.00 m. The maximum and minimum station discharges are 0.65 and 0.20 m3/s. Determine:

a. Operating head and capacity of the pump station when both pumps are operating.
b. Operating head and discharge of each pump.
c. Corresponding head and discharge given on the manufacturer’s head-capacity curve.

Pump Characteristic Curve Data Supplied by the Manufacturer

Head, m Discharge, m^3/s
20 0
15 0.30
10 0.45
5 0.50

ansver
Answers: 3

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Fluids at rest possess no flow energy. a)- true b)- false
Answers: 3
question
Engineering, 04.07.2019 18:10
Apipe with an outside diameter of 15 cm is exposed to an ambient air and surrounding temperature of -20°c. the pipe has an outer surface temperature of 65°c and an emissivity of 0.85. if the rate of heat loss from the pipe surface is 0.95 kw per meter of length, the external convective heat transfer coefficient (h) is: (a) 12.5 w/m"k (b) 18.6 w/mk (c) 23.7 w/mk (d) 27.9 w/mk (e) 33.5 w/mk
Answers: 1
question
Engineering, 04.07.2019 18:10
The higher the astm grain size number, the finer the gran is. a)-true b)-false
Answers: 2
question
Engineering, 04.07.2019 18:20
Ahe-xe mixture containing a 0.75 mole fraction of helium is used for cooling electronics in an avionics application. at a temperature of 300 k and atmospheric pressure, calculate the mass fraction of helium and the mass density, molar concentration and molecular weight of the mixture. if the cooling capacity is 10 l, what is the mass of the coolant?
Answers: 3
You know the right answer?
The data for characteristic curves of a variable-speed pump supplied by a manufacturer are given bel...
Questions
question
Mathematics, 16.01.2020 02:31
question
Mathematics, 16.01.2020 02:31
question
History, 16.01.2020 02:31