subject
Engineering, 06.03.2020 17:36 kfliehman1

Write an HDL code for an 32-bit Universal Shift Register with a positive-edge sensitive clock, a synchronous enable (highest priority), and an asynchronous negative-edge sensitive reset. The register can be loaded with serial in (1-bit) or parallel in (32-bit), and can be read serially (1-bit) or in parallel (32- bit). Also the register can perform left or right shift with a selection bit (1 for left shift, and 0 for right shift). b) Write a testbench for the module you wrote in (a) to test all of the corner cases.

ansver
Answers: 3

Another question on Engineering

question
Engineering, 04.07.2019 18:10
True or false (explain) (110)[111] is a slip system in bcc metals . the {111} family in fcc contains 8 planes. resolved shear stress (rss) in single crystals is just related to the applied stress. critical resolved shear stress (crss) in single crystal metals is direct proportional to the number of defects in the structure
Answers: 2
question
Engineering, 04.07.2019 18:20
Along 8-cm diameter steam pipe whose external surface temperature is 900c connects two buildings. the pipe is exposed to ambient air at 70c with a wind speed of 50 km/hr blowing across the pipe. determine the heat loss from the pipe per unit length. (b) air at 500c enters a section of a rectangular duct (15 cm x 20 cm) at an average velocity of 7 m/s. if the walls of the duct are maintained at 100c. a) the length of the tube for an exit temperature of the air to be 40 0c. b)the rate of heat transfer from the air. c) the fan power needed to overcome the pressure drop in this section of the duct.
Answers: 1
question
Engineering, 04.07.2019 19:10
An external consultant recommends that a plant installs a bank of capacitors for power factor correction. this will reduce the peak electrical demand charges by an average of 93 kw every month. the plant current pays $13 per kw in peak demand charges. the capacitor bank will include 223 kw of fixed capacitors, and 183 of variable capacitors. the fixed capacitors cost $59 per kw, and the variable capacitors will cost $65 per kw. the consultant charges 21% of the equipment costs to install the capacitors. because this project will reduce the demand for the electric utility, they are prepared to provide a one-time rebate of $42 per kw of reduced demand. what is the simple payback period for this project (in years)?
Answers: 2
question
Engineering, 04.07.2019 19:20
Apiping systems consists of 6 m of 6-std type k and 12 m of 4-std type k, both drawn copper tubing. the system conveys ethylene glycol at a rate of 0.013 m3/s. the pressure drop across the system is to be calculated. there are two 90° elbows in the 6-in pipe, a reduction from the 6-in pipe to the 4-in pipe and four 90° elbows in the 4-in pipe. all fittings are soldered (same as flanged) and regular. the inlet and outlet of the system are at the same height.
Answers: 1
You know the right answer?
Write an HDL code for an 32-bit Universal Shift Register with a positive-edge sensitive clock, a syn...
Questions
question
Mathematics, 11.11.2020 16:10
question
History, 11.11.2020 16:10
question
History, 11.11.2020 16:10
question
Mathematics, 11.11.2020 16:10
question
Mathematics, 11.11.2020 16:10