subject
Engineering, 28.02.2020 00:38 mikehager4321

Circular copper rods of diameter D=1mm and length L=25mm areused to enhance heat transfer from a surface that is maintained atTs,1=100 deg. C. One end of the rod is attached tothis surface (at x=o), hile the other end (at x=25mm) is joined toa second surface that is maintained at Ts,2=0deg. C. Air flowing between the surfaces (and over the rods)is also at a temperature T?= 0 deg. C, and has a convectioncoefficient of h=100 w/m2kelvin.

a. What is the rate of heat transfer by convection from a singlecopper rod to air?
b. What is the total rate of heat transfer from a 1 m x 1 m section of the surface at 100 deg. C, if a bundle of the rods is installed on 4-mm centers?

ansver
Answers: 3

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Coiled springs ought to be very strong and stiff. si3n4 is a strong, stiff material. would you select this material for a spring? explain.
Answers: 2
question
Engineering, 04.07.2019 18:10
Atmospheric air has a temperature (dry bulb) of 80° f and a wet bulb temperature of 60° f when the barometric pressure is 14.696 psia. determine the specific humidity, grains/lb dry air. a. 11.4 c. 55.8 d. 22.5 b. 44.1
Answers: 1
question
Engineering, 04.07.2019 18:10
An air compression refrigeration system is to have an air pressure of 100 psia in the brine tank and an allowable air temperature increase of 60°f for standard vapor compression cycle temperatures of 77 f entering the expansion cylinder and 14 f entering the compression cylinder, calculate the coefficient of performance a. 2.5 b 3.3 c. 4.0 d. 5.0
Answers: 3
question
Engineering, 04.07.2019 18:20
Athin walled concentric tube exchanger is used to cool engine oil from 160°c to 60°c with water that is available at 25°c acting as a coolant. the oil and water flow rates are each at 2 kg/s, and the diameter of the inner tube is 0.5 m and the corresponding value of the overall heat transfer coefficient is 250 w/m2. oc. how long must the heat exchanger be to accomplish the desired cooling? cpwater=4.187 kj/kg-candcpengine el=2.035 kj/kg·°c, oil . 120]
Answers: 1
You know the right answer?
Circular copper rods of diameter D=1mm and length L=25mm areused to enhance heat transfer from a sur...
Questions
question
Mathematics, 22.09.2019 03:50
question
Geography, 22.09.2019 03:50
question
Arts, 22.09.2019 03:50
question
Mathematics, 22.09.2019 03:50
question
Mathematics, 22.09.2019 03:50
question
Business, 22.09.2019 03:50