subject
Engineering, 19.02.2020 02:51 shmote12

Assume that the water temperature is 10°C and the depth of the settling tank is 3.0 m. Calcium carbonate precipitates with a relative density of 1.20 and diameter of 0.10 mm to be removed in a settling tank after softening treatment. Assume discrete particle settling. At 10°C the density and viscosity of water are 999.77 kg/m3 and 1.308x10-3 kg/m. s.
a. Calculate the theoretical settling velocity (cm/s), tank loading (m3 /m2 /d) and detention time (h) required for the removal.
b. How will the settling velocity change, if the viscosity, particle diameter, and the relative density increases by 10%? How will the settling velocity change if the water temperature is 25 oC instead of 10 oC? Vary only one parameter at a time.

ansver
Answers: 1

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Apump is used to circulate hot water in a home heating system. water enters the well-insulated pump operating at steady state at a rate of 0.42 gal/min. the inlet pressure and temperature are 14.7 lbf/in.2, and 180°f, respectively; at the exit the pressure is 60 lbf/in.2 the pump requires 1/15 hp of power input. water can be modeled as an incompressible substance with constant density of 60.58 lb/ft3 and constant specific heat of 1 btu/lb or. neglecting kinetic and potential energy effects, determine the temperature change, in °r, as the water flows through the pump.
Answers: 1
question
Engineering, 04.07.2019 18:10
Abrake has a normal braking torque of 2.8 kip in and heat-dissipating cast-iron surfaces whose mass is 40 lbm. suppose a load is brought to rest in 8.0 s from an initial angular speed of 1600 rev/min using the normal braking torque; estimate the temperature rise of the heat dissipating surfaces.
Answers: 3
question
Engineering, 04.07.2019 18:10
Determine whether or not it is possible to compress air adiabatically from k to 140 kpa and 400 k. what is the entropy change during this process?
Answers: 3
question
Engineering, 04.07.2019 18:10
The flow rate of air through a through a pipe is 0.02 m5/s. a pitot static tube is placed in the flow. the radius of the pitot static tube is 1 mm. assuming the flow to be steady and the air to be at 300k, calculate the difference in total and static pressure if the diameter of the pipe is: (a) d 0.1 m d 0.05 m (c) d 0.01 m
Answers: 2
You know the right answer?
Assume that the water temperature is 10°C and the depth of the settling tank is 3.0 m. Calcium carbo...
Questions
question
Mathematics, 07.04.2021 19:20
question
Mathematics, 07.04.2021 19:20
question
Mathematics, 07.04.2021 19:20