subject
Engineering, 18.02.2020 02:22 SarahBelle5663

The hydrogenolysis of thiophene C4H4S) has been studied at 235-265 °C over a cobalt-molyb- date catalyst, using a CSTR containing 8.16 g of catalyst. The stoichiometry of the system can be represented by

C4H4S+3H2 → C4H8+ H2S Reaction1
C4H8+ H2 → C4H10 Reaction 2

All species are gaseous at reaction conditions. The feed to the CSTR consisted of a mixture of thiophene, hydrogen, and hydrogen sulfide. The mole fractions of butene (C4Hg), butane (C4Hio), and hydrogen sulfide in the reactor effluent were measured. The mole fractions of hydrogen and thiophene were not measured. The data from one particular experimental run are given below:

Total pressure in reactor= 832 mmHg
Feed rate

Thiophene= 0.653 x 10^-4 g mol/min
Hydrogen= 4.933 × 10^-4 g·mol/min
Hydrogen sulfide= 0

Mole fractions in effluent
H2S =0.0719
Butenes = 0.0541

Calculate -rT (the rate of disappearance of thiophene) and the partial pressures of thiophene, hydrogen, hydrogen sulfide, butenes (total), and butane in the effluent. You may assume that the ideal gas laws are valid.

ansver
Answers: 2

Another question on Engineering

question
Engineering, 04.07.2019 18:10
The higher the astm grain size number, the finer the gran is. a)-true b)-false
Answers: 2
question
Engineering, 04.07.2019 18:20
Have a greater impact on maintenance productivity than any other support group. (clo5) a)-the top management b)-inventory and purchasing c)-sub-contracting d)-cmms
Answers: 2
question
Engineering, 04.07.2019 18:20
Along 8-cm diameter steam pipe whose external surface temperature is 900c connects two buildings. the pipe is exposed to ambient air at 70c with a wind speed of 50 km/hr blowing across the pipe. determine the heat loss from the pipe per unit length. (b) air at 500c enters a section of a rectangular duct (15 cm x 20 cm) at an average velocity of 7 m/s. if the walls of the duct are maintained at 100c. a) the length of the tube for an exit temperature of the air to be 40 0c. b)the rate of heat transfer from the air. c) the fan power needed to overcome the pressure drop in this section of the duct.
Answers: 1
question
Engineering, 04.07.2019 18:20
An open feedwater heater operates at steady state with liquid entering at inlet 1 with t? = 40°c and pl = 1 .2 mpa. water vapor att2-200°c and p2 = 1.2 mpa enters at inlet 2. saturated liquid water exits with a pressure of pa 1.2 mpa. neglect heat transfer with the surroundings and all kinetic and potential energy effects, determine the mass flow rate of steam at inlet 2 if the mass flow rate of liquid water at inlet 1 is given as 2 kg/s.
Answers: 3
You know the right answer?
The hydrogenolysis of thiophene C4H4S) has been studied at 235-265 °C over a cobalt-molyb- date cata...
Questions
question
Mathematics, 07.09.2021 07:30
question
Mathematics, 07.09.2021 07:30
question
Mathematics, 07.09.2021 07:30
question
Mathematics, 07.09.2021 07:30
question
Mathematics, 07.09.2021 07:30
question
Biology, 07.09.2021 07:40