subject
Engineering, 11.02.2020 19:21 dominguezjose625

The liquid phase reaction:
A+B→C
Follows an elementary rate law and is carried out isothermally in a flow system. The concentrations of A and B in the feed streams are 2 mol/L before mixing. The volumetric flow rate of each stream is 5 dm3 min, and the entering temperature is 300 K. The streams are mixed immediately before entering. Two reactors are available. One is a gray 200 dm3 CSTR that can be heated to 77 °C or cooled to 0 °C. The other is a white 800 dm PFR operated at 300 K that cannot be heated or cooled but may be painted black or red. Note that k = 0.07 dm3/mol/min at 300 K and E-20 kcal/mol
A) Which reactor would and what conditions do you recommend? Explaining the reason for your choice. Back up your reasoning with calculations.
B) How long would it take to achieve 90% conversion in a 200 dm3 batch reactor with initial concentrations of A and B at 1 mol/L and operated at 77 °C?
C) What would be your answer to part (b) if at 0 °C?
D) What conversion would be obtained if the CSTR and PFR were operated at 300 K and connected in series? In parallel with 5 dm min of the mixture to each?
E) What can you say about the various reactor types based on the above?

ansver
Answers: 3

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Items are similar to the free issue items, but their access is limited. (clo5) a)-bin stock items free issue b)-bin stock controlled issue c)-critical or insurance spares d)-rebuildable spares e)-consumables
Answers: 1
question
Engineering, 04.07.2019 18:10
Which from the following instrument is commonly used to detect the high pitch butzing sound in bearings? [clo4] a)-digital ultrasonic meter b)-infrared camera c)-spectroscopic d)-vibrometer
Answers: 2
question
Engineering, 04.07.2019 18:10
Awall of 0.5m thickness is to be constructed from a material which has average thermal conductivity of 1.4 w/mk. the wall is to be insulated with a material having an average thermal conductivity of 0.35 w/mk so that heat loss per square meter shall not exceed 1450 w. assume inner wall surface temperature of 1200°c and outer surface temperature of the insulation to be 15°c. calculate the thickness of insulation required.
Answers: 3
question
Engineering, 04.07.2019 18:20
Select any two (2) areas of applications of chain-drive. (clo4) a)-permanent lubrication necessary b)-hydraulic forklift truck operation c)-rigging and heavy moving materials d)-relatively high maintenance costs e)-costlier than belt drives
Answers: 2