subject
Engineering, 20.12.2019 02:31 danaya111

An element for sensing local shear stress is positioned in a flat plate 0.40 meter from the leading edge. the element simply consists of a small plate, mounted flush with the wall, and the shear force is measured on the plate. the fluid flowing by the plate is air with a free-stream velocity of 30 m/s, a density of 1.2 kg/m3 and a kinematic viscosity of 1.5 × 10-5 m2/s. the boundary layer is tripped at the leading edge. what is the magnitude of the force due to shear stress acting on the element?

ansver
Answers: 1

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Ifa component is made of two or more materials with different modulus of elasticity (e), it is called a composite member and we calculate the factor·n". mention the formula for calculating n". also, ifn> 1, explain what will happen to the 1. transformed.gi) ifn 1, what will happen to the material when transformed material when
Answers: 1
question
Engineering, 04.07.2019 18:20
Air is compressed isentropically from an initial state of 300 k and 101 kpa to a final temperature of 1000 k. determine the final pressure using the following approaches: (a) approximate analysis (using properties at the average temperature) (b) exact analysis
Answers: 1
question
Engineering, 04.07.2019 18:20
Along 8-cm diameter steam pipe whose external surface temperature is 900c connects two buildings. the pipe is exposed to ambient air at 70c with a wind speed of 50 km/hr blowing across the pipe. determine the heat loss from the pipe per unit length. (b) air at 500c enters a section of a rectangular duct (15 cm x 20 cm) at an average velocity of 7 m/s. if the walls of the duct are maintained at 100c. a) the length of the tube for an exit temperature of the air to be 40 0c. b)the rate of heat transfer from the air. c) the fan power needed to overcome the pressure drop in this section of the duct.
Answers: 1
question
Engineering, 06.07.2019 03:20
An air-conditioning system consists of a heating section and an evaporative cooler. air enters the heating section at 10°c and 70 percent relative humidity at a rate of 30m^3/min, and it leaves the evaporative cooler at 20°c and 60 percent relatively humidity. if the air conditioning system operates at a total pressure of 98 kpa, determine (a) the temperature and relative humidity of the air when it leaves the heating section, (b) the rate of heat transfer in the heating section, and (c) the rate of water added to air in the evaporative cooler
Answers: 2
You know the right answer?
An element for sensing local shear stress is positioned in a flat plate 0.40 meter from the leading...
Questions
question
Mathematics, 13.03.2020 06:55
question
Mathematics, 13.03.2020 06:57
question
Computers and Technology, 13.03.2020 07:01
question
Mathematics, 13.03.2020 07:02