subject
Engineering, 14.12.2019 00:31 saniyawilliams1207

The flow rate to a fine-bubble aeration basin is 21.5 mgd at 20°c with an influent bod concentration of 180 mg/l and 31 mg/l of ammonia. the effluent concentration is 10 mg/l of bod and no ammonia. according to the aeration equipment manufacturer, at the local operating conditions, for this equipment otr = 3.0 lb o2/hp-hr and ote = 25%. calculate:

a) the total oxygen demand, in lb/day.
b) the power required to operate the aeration system, in hp.
c) the air flow rate, in ft3 /min

ansver
Answers: 1

Another question on Engineering

question
Engineering, 03.07.2019 15:10
If you were designing a bumper for a car, would you prefer it to exhibit elastic or plastic deformation? why? consider the functions of a bumper in both a minor "fender-bender" and a major collision.
Answers: 1
question
Engineering, 04.07.2019 18:10
Refrigerant 134a enters an insulated compressor operating at steady state as saturated vapor at -26°c with a volumetric flow rate of 0.18 m3/s. refrigerant exits at 9 bar, 70°c. changes in kinetic and potential energy from inlet to exit can be ignored. determine the volumetric flow rate at the exit, in m3/s, and the compressor power, in kw.
Answers: 1
question
Engineering, 04.07.2019 18:10
Afull journal bearing has a journal diameter of 27 mm, with a unilateral tolerance of -0.028 mm. the bushing bore has a diameter of 27.028 mm and a unilateral tolerance of 0.04 mm. the l/d ratio is 0.5. the load is 1.3 kn and the journal runs at 1200 rev/min. if the average viscosity is 50 mpa-s, find the minimum film thickness, the power loss, and the side flow for the minimum clearance assembly.
Answers: 1
question
Engineering, 04.07.2019 18:10
The flow rate of air through a through a pipe is 0.02 m5/s. a pitot static tube is placed in the flow. the radius of the pitot static tube is 1 mm. assuming the flow to be steady and the air to be at 300k, calculate the difference in total and static pressure if the diameter of the pipe is: (a) d 0.1 m d 0.05 m (c) d 0.01 m
Answers: 2
You know the right answer?
The flow rate to a fine-bubble aeration basin is 21.5 mgd at 20°c with an influent bod concentration...
Questions
question
English, 14.05.2021 17:10
question
Mathematics, 14.05.2021 17:10
question
Mathematics, 14.05.2021 17:10
question
Mathematics, 14.05.2021 17:10