subject
Engineering, 14.11.2019 19:31 misstaejailicious200

Along, cylindrical electrical heating element of diameter d= 10 mm, length l= 0.25 m, thermal conductivity k = 240 w/m-k, density rho= 2700 kg/m3, and the specific heat c p=900 j/kg-k. the heater element is installed in a duct in which the air is flowing at a velocity of 10 m/s, and at an air temperature of 27oc. and 10 m/s, respectively. neglecting radiation, the steady state surface temperature of the rod is 3300c. a) what is the averaged heat convecition h ? b) determine per unit length of the heater, electrical energy is being dissipation rate. c) if the heater is activated from an initial temperature of 500c, estimate the time required for the surface temperature to come to 100c of its steady-state value.

ansver
Answers: 3

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Asingle-geared blanking press has a stroke of 200 mm and a rated capacity of 320 kn. a cam driven ram is assumed to be capable of delivering the full press load at constant force during the last 15 percent of a constant-velocity stroke. the camshaft has an average speed of 90 rev/min and is geared to the flywheel shaft at a 6: 1 ratio. the total work done is to include an allowance of 16 percent for friction a) estimate the maximum energy fluctuation b) find the rim weight for an effective diameter of 1.2 m and a coefficient of speed fluctuation of 0.10
Answers: 1
question
Engineering, 04.07.2019 18:20
Vibration monitoring this technique uses the noise or vibration created by mechanical equipment and in seme cases by plant systems to detemine their actual condtion. a)- true b)- false
Answers: 2
question
Engineering, 04.07.2019 18:20
Athin walled concentric tube exchanger is used to cool engine oil from 160°c to 60°c with water that is available at 25°c acting as a coolant. the oil and water flow rates are each at 2 kg/s, and the diameter of the inner tube is 0.5 m and the corresponding value of the overall heat transfer coefficient is 250 w/m2. oc. how long must the heat exchanger be to accomplish the desired cooling? cpwater=4.187 kj/kg-candcpengine el=2.035 kj/kg·°c, oil . 120]
Answers: 1
question
Engineering, 04.07.2019 18:20
A2-m rigid tank initially contains saturated water vapor at 100 kpa. the tank is connected to a supply line through a valve. steam is flowing in the supply line at 600 kpa and 300 c. the valve is opened, and steam is allowed to enter the tank until the pressure in the tank reaches the line pressure, at which point the valve is closed. a thermometer placed in the tank indicates that the temperature at the final state is 200°c. determine (a) the mass of steam that has entered the tank (b) the amount of heat transfer.
Answers: 3
You know the right answer?
Along, cylindrical electrical heating element of diameter d= 10 mm, length l= 0.25 m, thermal conduc...
Questions
question
Mathematics, 29.01.2020 23:52
question
Geography, 29.01.2020 23:52
question
Social Studies, 29.01.2020 23:53