Engineering, 22.10.2019 19:50 Nowellkwaku

Athree-phase wye-connected synchronous generator supplies a network through a transmission line. the network can absorb or deliver power while maintaining its terminal voltage constant. the four-pole, 60 hz generator data rating are 40 mva and 26 kv with a 0.85 p. u. reactance. the field current of the generator can be adjusted to regulate the excitation (induced) voltage from 0.75 to 1.5 times the rated voltage. the network voltage rating is 24 kv. the transmission line impedance and length are 0.07+j0.5 ω/mi and 8 mi. (a) calculate the generator induced voltage versus power factor, if the network voltage is at the rated value, and the bus absorbs the generator rated power. after this, plot the voltage regulation of the system versus the power factor. use the induced voltage and network voltage for plotting the voltage regulation. the leading power factor varies from 0.5 to 1. what power factor corresponds to 10% regulation? (b) plot the maximum power (power angle is 90°) versus induced voltage. determine the required induced voltage that allows the safe transfer of maximum power from the generator to the network (not to exceed the generator rating). assume that the network voltage is the same as in part (a). the excitation voltage is the variable.

ansver
Answers: 2

Another question on Engineering

question
Engineering, 04.07.2019 18:20
Find the kinematic pressure of 160kpa. for air, r-287 j/ kg k. and hair al viscosity of air at a temperature of 50°c and an absolute (10 points) (b) find the dynamic viscosity of air at 110 °c. sutherland constant for air is 111k
Answers: 3
question
Engineering, 04.07.2019 19:10
10 kg of co2 is initially contained at 400 kpa and 300 k. the gas constant for carbon dioxide is 189 j/lkg k) and has a specific heat ratio, k, of 1.289. isentropic expansion then occurs until the pressure is 200 kpa. a) determine the initial volume of co2 in m. b) determine the final temperature in k. c) determine the work done by the system during the expansion kl.
Answers: 2
question
Engineering, 04.07.2019 19:20
To save energy, the air supply to a 2000 ft office has been shut off overnight and the room temperature has dropped to 40°f. in the morning, the thermostat is reset to 70°f and warm air at 120 f begins to flov in at 200ft'/min. the air is well mixed within the room, and an equal mass flow of air at room temperature (changing with time) is withdrawn through a return duct. the air pressure is nearly 1 atm everywhere. ignoring heat transfer with the surroundings and kinetic and potential energy effects, estimate how long it takes for the room temperature to reach 70°f. plot the room temperature as a function of time.
Answers: 1
question
Engineering, 04.07.2019 19:20
Acompressor compresses a gas, a pump compresses a liquid. for a given pressure ratio, why does it take more work to compress a gas in a compressor than a liquid in a pump? a)- for a given pressure ratio the average specific volume for a gas is much higher than the average specific volume for a liquid. b)- there is no difference. the only difference is the amount of heat generated (not work) c)- for a given pressure ratio the average volurge for a gas is much higher than the average volume for a liquid. d)-there is no difference
Answers: 3