Ihave these components:
- 40 rooms
- guard house
- speaker system
- high alert indicator
- mild alert indicator - in use indicator

i was given these function of the components:
a) the intercom must have a connection from the gate to each room and from each room to another room. to reduce cable runs and minimise cost, a single cat5 cable runs from the room to a central switch in the building. another cable runs from the switch to the gate. this is shown in figure 1 below.
b) connection is establish by entering the room number into the keypad following by some call button. the room number is translated into a unique binary address embedded in the system.
c) when a room is called the buzzer is sounded and a visual indicator blinks on panel in the room.
d) if the call is accepted and the line is busy, all other terminals will have the in use indicator lit.
e) each alert indicator must have a unique code. these function is only activated by the college manager to all connected device. when alert is high, the buzzer must also ring for 30 seconds.

i am confused about drawing a flow chart giving the input conditions and discuss the process for room 5 on the intercom with the gate.

, any idea or close to my question is very much appreciated.

ansver
Answers: 2

Another question on Engineering

question
Engineering, 04.07.2019 18:10
If a particle moves along a path such that r : (3 sin t) m and ? : 2t rad, where t is in seconds. what is the particle's acceleration in m/s in 4 seconds? a)- 16.43 b)- 16.29 c)- 15.21 d)- 13.79
Answers: 1
question
Engineering, 04.07.2019 19:20
Apure substance is a)-mixture of various chemical elements or compounds b)-substance that has a fixed chemical composition throughout c)-mixture that is homogeneous (such as air) d)-all the answers
Answers: 3
question
Engineering, 04.07.2019 19:20
Amass-spring-viscous damper system of mass 3 kg has a frequency of 100 rad/s and is critically damped. its initial conditions are x(0)-3 mm and (0)-2.3 m/s. does the system overshoot its equilibrium position? prove your answer
Answers: 1
question
Engineering, 05.07.2019 04:30
Technician a says that in a worm gear steering system, most excessive steering free play is usually found in the gearbox. technician b says that in a rack-and-pinion steering system, excessive free play can be found in the bushings. who is correct?
Answers: 2
You know the right answer?
Ihave these components:
- 40 rooms
- guard house
- speaker system
- high al...
Questions
question
Social Studies, 25.09.2019 15:50
question
English, 25.09.2019 15:50
question
Mathematics, 25.09.2019 15:50