subject
Engineering, 09.10.2019 20:00 shiny9362

A5­stage single pipeline computer uses the pipeline mentioned in the lecture (not the book). it resolves the direction and target of a conditional branch instruction at the end of its third pipeline stage. when a branch is detected, the pipeline quashes the subsequent instructions already in the pipeline and stalls until the branch is resolved. after that, execution resumes at the target or the fall-through instruction, based on the branch condition. how many cycles does the pipeline stall upon a branch? (i. e, how many cycles are lost? )

ansver
Answers: 1

Another question on Engineering

question
Engineering, 04.07.2019 18:10
Which one from below is not one of the reasons of planning failures? (clo3) a)-planner is careless. b-planner spend less time in the field but more time on the desk c)-planner is not qualified d)-planner does not have sufficient time to properly plan
Answers: 3
question
Engineering, 04.07.2019 18:20
Along 8-cm diameter steam pipe whose external surface temperature is 900c connects two buildings. the pipe is exposed to ambient air at 70c with a wind speed of 50 km/hr blowing across the pipe. determine the heat loss from the pipe per unit length. (b) air at 500c enters a section of a rectangular duct (15 cm x 20 cm) at an average velocity of 7 m/s. if the walls of the duct are maintained at 100c. a) the length of the tube for an exit temperature of the air to be 40 0c. b)the rate of heat transfer from the air. c) the fan power needed to overcome the pressure drop in this section of the duct.
Answers: 1
question
Engineering, 04.07.2019 19:20
Acommercial grade cubical freezer, 4 m on a side, has a composite wall consisting of an exterior sheet of 5.0-mm thick plain carbon steel (kst= 60.5 w/m k), an intermediate layer of 100-mm thick polyurethane insulation (kins 0.02 w/m k), and an inner sheet of 5.0- mm thick aluminium alloy (kal polyurethane insulation and both metallic sheets are each characterized by a thermal contact resistance of r 2.5 x 104 m2 k/w. (a) what is the steady-state cooling load that must be maintained by the refrigerator under conditions for which the outer and inner surface temperatures are 25°c and -5°c, respectively? (b) for power saving purpose, which wall material should be increased/reduced in. thickness in order to reduce 50% of the cooling load found in part (a)? redesign the thickness of the proposed material. 177 w/m-k). adhesive interfaces between the q=575.93 w
Answers: 2
question
Engineering, 06.07.2019 04:20
Derive the 2-d finite difference equation for a uniform grid for a node: a) at a plane surface with a uniform heat flux b) at an internal corner with convection
Answers: 1
You know the right answer?
A5­stage single pipeline computer uses the pipeline mentioned in the lecture (not the book). it reso...
Questions
question
Mathematics, 22.04.2021 19:40
question
English, 22.04.2021 19:40
question
English, 22.04.2021 19:40
question
Mathematics, 22.04.2021 19:40
question
Mathematics, 22.04.2021 19:40