subject
Engineering, 04.10.2019 22:20 PushyGorilla

The length of a 60 w , 240 ω light bulb filament is 60 cm . part a if the potential difference across the filament is 120 v , what is the strength of the electric field inside the filament? express your answer in volts per meter. e e = nothing v/m submitrequest answer part b suppose the length of the bulb's filament were doubled without changing its diameter or the potential difference across it. what would the electric field strength be in this case? express your answer in volts per meter. e e = nothing v/m submitrequest answer part c remembering that the current in the filament is proportional to the electric field, what is the current in the filament following the doubling of its length? express your answer in amperes. i i = nothing a submitrequest answer part d what is the resistance of the filament following the doubling of its length? express your answer in ohms. r r = nothing ω submitrequest answer provide feedback next

ansver
Answers: 3

Another question on Engineering

question
Engineering, 04.07.2019 18:20
Find the minimum film thickness for a journal bearing with the data below. shaft diameter, d-50 mm, clearance ratio, cdratio? 0.001, shaft speed, n 2000 rpm; bearing length. i 200 mm; eccentricity ration, ? -0.55. ( note, cdratio-ca/d) the minimum film thickness is um
Answers: 2
question
Engineering, 04.07.2019 18:20
Modern high speed trains do not have perpendicular expansion gaps where rails are joined end-to-end any more they are mostly welded together but what might happen if there was a spell of particularly hot weather that causes inspection of the tracks?
Answers: 1
question
Engineering, 04.07.2019 19:10
Afoot bridge is made as a simple deck, 4 m long, with a cross section 2 m (wide) and 20 cm thick, and made of wood. the deck is supported at the two ends. the maximum load allowable on the bridge is 10 tons, provided it is uniformly distributed on the deck. to sense this load, a strain gauge is placed at the center of the bridge and its resistance is monitored. if the sensor has a nominal resistance of 350 s2 and a gauge factor of 3.6, what is the reading of the strain gauge at maximum load? the modulus of elasticity for the wood used in the construction is 10 gpa.
Answers: 2
question
Engineering, 04.07.2019 19:10
Asteel wire of 2 mm diameter is fixed between two points located 2 m apart. the tensile force in the wire is 250n, if its density of steel is given by 7830 kg/m3 the fundamental frequency of vibration hz? ?
Answers: 3
You know the right answer?
The length of a 60 w , 240 ω light bulb filament is 60 cm . part a if the potential difference acros...
Questions