subject
Engineering, 26.09.2019 21:30 Galaxie85111

Space-shuttle main engine is designed with the given criteria x design altitude = 60,000 feet (18,300 m), where atmospheric pressure is, patm=7171.64 pa= 1.04016 psi. at this altitude the exhaust jet is fully expanded. x nozzle exit mach number = 5.05 (calculated) x throat area = 93 square inches (600 cm2) x nozzle exit area = 50.265 square feet (4.6698 m2 ) x chamber total pressure = 2,747 pounds per square inch (18,940 kpa) at 100% power assuming you can use the 2-d shock/expansion theory: calculate the static pressure at the nozzle exit plane and the flow-turning angle right after the flow exits the nozzle at: x sea level, where patm = 101325 pa =14.696 psi x b) 100,000 feet, where patm = 1090.16 pa = 0.158 psi

ansver
Answers: 1

Another question on Engineering

question
Engineering, 04.07.2019 18:10
An air conditioning system consist of a 5 cm diameter pipe, operating at a pressure of 200 kpa. the air initially enters the pipe at 15°c with a velocity of 20 m/s and relative humidity of 80%. if the heat supply throughout the process is 960 w, determine the relative humidity and the temperature at the outlet
Answers: 3
question
Engineering, 04.07.2019 18:10
Assuming compressible flow of air and that the measurements are done at flagstaff a pitot static tube that gives the difference of total and static pressure measures 0.35 m of mercury. what is the velocity of air? assume the temperature to be 300k. (submit your excel or matlab calculation sheet)
Answers: 1
question
Engineering, 04.07.2019 18:20
Air flows over a heated plate àt a velocity of 50m/s. the local skin factor coefficient at a point on a plate is 0.004. estimate the local heat transfer coefficient at this point.the following property data for air are given: density = 0.88kg/m3 , viscosity 2.286 x 10 ^-5 kgm/s , k = 0.035w/mk ,cp = 1.001kj/kgk. use colburn reynolds analogy.
Answers: 1
question
Engineering, 04.07.2019 19:10
An external consultant recommends that a plant installs a bank of capacitors for power factor correction. this will reduce the peak electrical demand charges by an average of 93 kw every month. the plant current pays $13 per kw in peak demand charges. the capacitor bank will include 223 kw of fixed capacitors, and 183 of variable capacitors. the fixed capacitors cost $59 per kw, and the variable capacitors will cost $65 per kw. the consultant charges 21% of the equipment costs to install the capacitors. because this project will reduce the demand for the electric utility, they are prepared to provide a one-time rebate of $42 per kw of reduced demand. what is the simple payback period for this project (in years)?
Answers: 2
You know the right answer?
Space-shuttle main engine is designed with the given criteria x design altitude = 60,000 feet (18,30...
Questions
question
Chemistry, 28.12.2021 16:30