subject
Engineering, 17.09.2019 20:00 Thania3902

All instructions are given in the form of comments in the file. you are to again run the file in both gcc and visual studio (2017 or 2015 version). observe the outputs and make changes as asked.#include #pragma warning(disable : 4996) // needed in vs// cse 240 fall 2018 homework 2 question 3 (25 points)// note: you may notice some warnings when you compile in gcc or vs, that is okay.#define positive_1(x) ((x > 0) ? x : 0)#define polynomial_2(a, b) (a*a + 2*a + 4*a*b - b*b)int function_1(int a, int b) {return (a*a + 2*a + 4*a*b - b*b); }(a) run this program in visual studio(vs) and then again in gcc. note the output values for function_1 and polynomial_2.void part2(int x, int y) {int x_copy = x, y_copy = y; printf("function_1(x, y) = %d \n polynomial_2(x, y) = %d \n\n", function_1(++x, ++y), polynomial_2(++x_copy, ++y_copy)); (b) correct the program so that function_1 and polynomial_2 produce same correct output of 371.

ansver
Answers: 2

Another question on Engineering

question
Engineering, 03.07.2019 14:10
Amass of m 1.5 kg of steam is contained in a closed rigid container. initially the pressure and temperature of the steam are: p 1.5 mpa and t 240°c (superheated state), respectively. then the temperature drops to t2= 100°c as the result of heat transfer to the surroundings. determine: a) quality of the steam at the end of the process, b) heat transfer with the surroundings. for: p1.5 mpa and t 240°c: enthalpy of superheated vapour is 2900 kj/kg, specific volume of superheated vapour is 0. 1483 m/kg, while for t 100°c: enthalpy of saturated liquid water is 419kj/kg, specific volume of saturated liquid water is 0.001043m/kg, enthalpy of saturated vapour is 2676 kj/kg, specific volume of saturated vapour is 1.672 m/kg and pressure is 0.1 mpa.
Answers: 3
question
Engineering, 04.07.2019 18:10
Refrigerant 134a enters an insulated compressor operating at steady state as saturated vapor at -26°c with a volumetric flow rate of 0.18 m3/s. refrigerant exits at 9 bar, 70°c. changes in kinetic and potential energy from inlet to exit can be ignored. determine the volumetric flow rate at the exit, in m3/s, and the compressor power, in kw.
Answers: 1
question
Engineering, 04.07.2019 18:10
Afluid flows with a velocity field given by v=(x/t)i.. determine the local and convective accelerations when x=3 and t=1.
Answers: 2
question
Engineering, 04.07.2019 18:10
Items are similar to the free issue items, but their access is limited. (clo5) a)-bin stock items free issue b)-bin stock controlled issue c)-critical or insurance spares d)-rebuildable spares e)-consumables
Answers: 1
You know the right answer?
All instructions are given in the form of comments in the file. you are to again run the file in bot...
Questions
question
Social Studies, 15.10.2019 10:30
question
Mathematics, 15.10.2019 10:30